background image

©2022

88-4YCA4001-1A-EN

SAFETY SECTION

IIm

mp

po

orrtta

an

ntt

— This document contains a wiring

diagram, a parts list, and service information. This is
customer property and is to remain with this unit.
Please return to service information pack upon
completion of work.

W

WA

AR

RN

NIIN

NG

G

H

HA

AZ

ZA

AR

RD

DO

OU

US

S V

VO

OL

LT

TA

AG

GE

E!!

F

Fa

aiillu

urre

e tto

o ffo

ollllo

ow

w tth

hiiss W

Wa

arrn

niin

ng

g cco

ou

ulld

d rre

essu

ulltt iin

n

p

prro

op

pe

errtty

y d

da

am

ma

ag

ge

e,, sse

ev

ve

erre

e p

pe

errsso

on

na

all iin

njju

urry

y,, o

orr

d

de

ea

atth

h..

D

Diisscco

on

nn

ne

ecctt a

allll e

elle

eccttrriicc p

po

ow

we

err,, iin

nccllu

ud

diin

ng

g rre

em

mo

otte

e

d

diisscco

on

nn

ne

eccttss b

be

effo

orre

e sse

errv

viicciin

ng

g.. F

Fo

ollllo

ow

w p

prro

op

pe

err

llo

occkko

ou

utt//tta

ag

go

ou

utt p

prro

occe

ed

du

urre

ess tto

o e

en

nssu

urre

e tth

he

e p

po

ow

we

err

cca

an

nn

no

ott b

be

e iin

na

ad

dv

ve

errtte

en

nttlly

y e

en

ne

errg

giizze

ed

d..

W

WA

AR

RN

NIIN

NG

G

S

SA

AF

FE

ET

TY

Y A

AN

ND

D E

EL

LE

EC

CT

TR

RIIC

CA

AL

L H

HA

AZ

ZA

AR

RD

D!!

F

Fa

aiillu

urre

e tto

o ffo

ollllo

ow

w tth

hiiss W

Wa

arrn

niin

ng

g cco

ou

ulld

d rre

essu

ulltt iin

n

p

prro

op

pe

errtty

y d

da

am

ma

ag

ge

e,, sse

ev

ve

erre

e p

pe

errsso

on

na

all iin

njju

urry

y,, o

orr

d

de

ea

atth

h..

T

Th

he

esse

e sse

errv

viicciin

ng

g iin

nssttrru

uccttiio

on

nss a

arre

e ffo

orr u

usse

e b

by

y

q

qu

ua

alliiffiie

ed

d p

pe

errsso

on

nn

ne

ell o

on

nlly

y.. T

To

o rre

ed

du

ucce

e tth

he

e rriisskk o

off

e

elle

eccttrriicca

all ssh

ho

occkk,, d

do

o n

no

ott p

pe

errffo

orrm

m a

an

ny

y sse

errv

viicciin

ng

g

o

otth

he

err tth

ha

an

n tth

ha

att cco

on

ntta

aiin

ne

ed

d iin

n tth

he

esse

e o

op

pe

erra

attiin

ng

g

iin

nssttrru

uccttiio

on

nss u

un

nlle

essss y

yo

ou

u a

arre

e q

qu

ua

alliiffiie

ed

d tto

o d

do

o sso

o..

C

CA

AU

UT

TIIO

ON

N

G

GR

RO

OU

UN

ND

DIIN

NG

G R

RE

EQ

QU

UIIR

RE

ED

D!!

F

Fa

aiillu

urre

e tto

o iin

nssp

pe

ecctt o

orr u

usse

e p

prro

op

pe

err sse

errv

viicce

e tto

oo

ollss m

ma

ay

y

rre

essu

ulltt iin

n e

eq

qu

uiip

pm

me

en

ntt d

da

am

ma

ag

ge

e o

orr p

pe

errsso

on

na

all iin

njju

urry

y..

R

Re

ecco

on

nn

ne

ecctt a

allll g

grro

ou

un

nd

diin

ng

g d

de

ev

viicce

ess.. A

Allll p

pa

arrttss o

off tth

hiiss

p

prro

od

du

ucctt tth

ha

att a

arre

e cca

ap

pa

ab

blle

e o

off cco

on

nd

du

uccttiin

ng

g e

elle

eccttrriicca

all

ccu

urrrre

en

ntt a

arre

e g

grro

ou

un

nd

de

ed

d.. IIff g

grro

ou

un

nd

diin

ng

g w

wiirre

ess,, ssccrre

ew

wss,,

ssttrra

ap

pss,, cclliip

pss,, n

nu

uttss,, o

orr w

wa

assh

he

errss u

usse

ed

d tto

o cco

om

mp

plle

ette

e a

a

p

pa

atth

h tto

o g

grro

ou

un

nd

d a

arre

e rre

em

mo

ov

ve

ed

d ffo

orr sse

errv

viicce

e,, tth

he

ey

y m

mu

usstt

b

be

e rre

ettu

urrn

ne

ed

d tto

o tth

he

eiirr o

orriig

giin

na

all p

po

ossiittiio

on

n a

an

nd

d p

prro

op

pe

errlly

y

ffa

asstte

en

ne

ed

d..

W

WA

AR

RN

NIIN

NG

G

U

UN

NIIT

T C

CO

ON

NT

TA

AIIN

NS

S R

R--4

41

10

0A

A

R

RE

EF

FR

RIIG

GE

ER

RA

AN

NT

T!!

F

Fa

aiillu

urre

e tto

o u

usse

e p

prro

op

pe

err sse

errv

viicce

e tto

oo

ollss m

ma

ay

y rre

essu

ulltt iin

n

e

eq

qu

uiip

pm

me

en

ntt d

da

am

ma

ag

ge

e o

orr p

pe

errsso

on

na

all iin

njju

urry

y..

R

R--4

41

10

0A

A o

op

pe

erra

attiin

ng

g p

prre

essssu

urre

e e

ex

xcce

ee

ed

dss tth

he

e lliim

miitt o

off R

R--

2

22

2.. P

Prro

op

pe

err sse

errv

viicce

e e

eq

qu

uiip

pm

me

en

ntt iiss rre

eq

qu

uiirre

ed

d.. S

Se

errv

viicce

e

u

ussiin

ng

g o

on

nlly

y R

R--4

41

10

0A

A R

Re

effrriig

ge

erra

an

ntt a

an

nd

d a

ap

pp

prro

ov

ve

ed

d P

PO

OE

E

cco

om

mp

prre

esssso

orr o

oiill..

W

WA

AR

RN

NIIN

NG

G

S

SA

AF

FE

ET

TY

Y H

HA

AZ

ZA

AR

RD

D!!

O

Op

pe

erra

attiin

ng

g tth

he

e u

un

niitt w

wiitth

ho

ou

utt tth

he

e a

acccce

essss p

pa

an

ne

ellss

p

prro

op

pe

errlly

y iin

nsstta

alllle

ed

d m

ma

ay

y rre

essu

ulltt iin

n sse

ev

ve

erre

e p

pe

errsso

on

na

all

iin

njju

urry

y o

orr d

de

ea

atth

h..

D

Do

o n

no

ott o

op

pe

erra

atte

e tth

he

e u

un

niitt w

wiitth

ho

ou

utt tth

he

e e

ev

va

ap

po

orra

atto

orr ffa

an

n

a

acccce

essss p

pa

an

ne

ell o

orr e

ev

va

ap

po

orra

atto

orr cco

oiill a

acccce

essss p

pa

an

ne

ell iin

n

p

plla

acce

e..

W

WA

AR

RN

NIIN

NG

G

W

WA

AR

RN

NIIN

NG

G!!

T

Th

hiiss p

prro

od

du

ucctt cca

an

n e

ex

xp

po

osse

e y

yo

ou

u tto

o cch

he

em

miicca

allss

iin

nccllu

ud

diin

ng

g lle

ea

ad

d,, w

wh

hiicch

h a

arre

e kkn

no

ow

wn

n tto

o tth

he

e S

Stta

atte

e o

off

C

Ca

alliiffo

orrn

niia

a tto

o cca

au

usse

e cca

an

ncce

err a

an

nd

d b

biirrtth

h d

de

effe

eccttss o

orr

o

otth

he

err rre

ep

prro

od

du

uccttiiv

ve

e h

ha

arrm

m.. F

Fo

orr m

mo

orre

e iin

nffo

orrm

ma

attiio

on

n g

go

o

tto

o w

ww

ww

w..P

P6

65

5W

Wa

arrn

niin

ng

gss..cca

a..g

go

ov

v..

IIm

mp

po

orrtta

an

ntt:: Wear appropriate gloves, arm sleeve

protectors and eye protection when
servicing or maintaining this equipment.

IIm

mp

po

orrtta

an

ntt:: Air filters and media wheels or plates shall

meet the test requirements in UL 900.

Содержание 4YCA4024A1060A

Страница 1: ...uipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags stickers and labels that are attached t...

Страница 2: ...tr ri ic ca al l c cu ur rr re en nt t a ar re e g gr ro ou un nd de ed d I If f g gr ro ou un nd di in ng g w wi ir re es s s sc cr re ew ws s s st tr ra ap ps s c cl li ip ps s n nu ut ts s o or r...

Страница 3: ...Determine Unit Clearances 5 Step 3 Review Location and Recommendation Information 7 Step 4 Unit Installation 8 Step 5 Unit Startup 19 Sequence of Operation 21 Airflow Tables 23 Maintenance 25 Importan...

Страница 4: ...c ct t S Sh hi ip pm me en nt t 1 Check for damage after the unit is unloaded Report promptly to the carrier any damage found to the unit Do not drop the unit I Im mp po or rt ta an nt t To prevent da...

Страница 5: ...88 4YCA4001 1A EN 5 Step 2 Determine Unit Clearances Figure 1 Outline Drawing...

Страница 6: ...6 88 4YCA4001 1A EN Figure 2 Outline Drawing S St te ep p 2 2 D De et te er rm mi in ne e U Un ni it t C Cl le ea ar ra an nc ce es s...

Страница 7: ...serviceability maximum capacity and peak operating efficiency 2 Refer to the Installation section for instruction on converting the supply and return airflow covers to down airflow 3 The field assemb...

Страница 8: ...oof There must be a weatherproof seal where the duct enters the structure 5 Do not expose the unit to direct roof water runoff 6 Seal all holes through exterior walls in accordance with local codes 7...

Страница 9: ...ure 4 Converting Horizontal to Down Airflow HORIZONTAL SUPPLY AIR COVER SHEET METAL SCREWS HORIZONTAL RETURN AIR COVER Figure 5 Lifting and Rigging Base of unit rest on top of curb r ails Drip lip on...

Страница 10: ...ta al ll la at ti io on n F Fr ra am me e M Mo ou un nt ti in ng g For rooftop applications using field fabricated frame and ducts use the following procedure 1 Prepare the hole in the roof in advanc...

Страница 11: ...and weatherproofed in accordance with local codes 11 Access and service clearances for the unit must be given careful consideration when locating the duct entrance openings Figures Step 2 Determine U...

Страница 12: ...w these guidelines for ductwork construction Connections to the unit should be made with three 3 inch canvas connectors to minimize noise and vibration transmission Elbows with turning vanes or splitt...

Страница 13: ...ol ll lo ow w t th he e s sa af fe et ty y w wa ar rn ni in ng g e ex xa ac ct tl ly y c co ou ul ld d r re es su ul lt t i in n s se er ri io ou us s i in nj ju ur ry y d de ea at th h o or r p pr r...

Страница 14: ...lt at pressures lower than 5 5 inches water column at the unit inlet If the supply line pressure is below the minimum supply pressure indicated on the unit nameplate contact the gas supply company Fol...

Страница 15: ...32 hex wrench or flat head screwdriver N No ot te e For manifold pressures and orifice sizes for gas with other BTU ratings contact the local gas utility Manifold pressure should be 3 5 inches water c...

Страница 16: ...on E El le ec ct tr ri ic ca al l C Co on nn ne ec ct ti io on ns s Electrical wiring and grounding must be installed in accordance with local codes or in the absence of local codes with the National...

Страница 17: ...supply agrees with equipment and heater nameplate 3 Low voltage wiring to be 18 AWG minimum conductor 4 The thermostat on the Gas Electric unit must provide a G signal in the cooling mode only During...

Страница 18: ...ring within the unit and make sure all connections are tight Replace and secure all electrical box covers and access panels before leaving the unit or turning on the power to the unit H Hi ig gh h A A...

Страница 19: ...t period of time install pressure gauges on the gauge ports of the discharge and suction line valves behind the Compressor access panel Check the suction and discharge pressures and compare them to th...

Страница 20: ...N No ot te e Blue smoke produced by the heat exchanger during the initial burner firing is caused by a thin film of oil on the surface of the heat exchanger This oil will burn off quickly 8 Set the th...

Страница 21: ...ignition has been achieved the delay to indoor fan on period begins timing and after approximately 45 seconds the indoor blower motor IDM will be energized and will continue to run during the heating...

Страница 22: ...hes High Limit switch protection device open Steady ON Normal Call for Heat 5 Flashes Flame sensed and gas valve not energized or flame sensed and no W signal 6 Flashes Flame Rollout Switch open 7 Fla...

Страница 23: ...47 255 263 270 277 283 289 294 Cooling High 0 CFM 1276 1229 1186 1137 1087 1039 994 950 913 874 WATTS 230 239 247 255 263 270 277 283 289 294 Heat Low 0 CFM 1116 1060 1006 950 898 849 805 760 723 668...

Страница 24: ...1408 1355 WATTS 483 499 514 528 543 557 568 583 592 601 Heat Low 0 CFM 1928 1876 1819 1764 1714 1660 1602 1543 1482 1437 WATTS 526 541 557 573 586 601 613 627 641 651 Heat High 0 CFM 1829 1769 1702 16...

Страница 25: ...ine these areas of the unit filters for cleaning or replacement motors and drive system components economizer gaskets for possible replacement safety controls for mechanical cleaning electrical compon...

Страница 26: ...26 88 4YCA4001 1A EN N No ot te es s...

Страница 27: ...88 4YCA4001 1A EN 27 N No ot te es s...

Страница 28: ...anstandardair com The AHRI Certified mark indicates company participation in the AHRI Certification program For verification of individual certified products go to ahridirectory org The manufacturer h...

Отзывы: