Installation and operating manual – TUM1072
TEF 2440
Perimeter / Obstruction light
Dimensions
External dimensions:
Страница 1: ...nual TUM1072 TEF 2440 Perimeter Obstruction light Perimeter Obstruction Light LED TEF 2440 Document properties TUM1072 Revision Comment Date By F Changed tyoe of cable gland and cable diameter range Converted to word 25 10 2022 CKR ...
Страница 2: ...ies TUM1072 1 Warnings and risk levels 3 General information 3 Marking and intended use 4 Special conditions for safe use 5 Technical data 5 Product description 5 Transport and storage 5 Mounting and installation 6 Mounting 6 Dimensions 8 External dimensions 8 Commissioning 9 Maintenance and cleaning 9 Disposal 9 Compliance Conformity 10 ...
Страница 3: ...isk of injuries or damage to equipment NOTICE Non compliance with the instruction may result in reduced lifetime of equipment malfunctions etc General information Before installation make sure to read and understand this installation and operating manual Observe national assembly and installation regulations Always contact the manufacturer if anything is unclear or if you notice any faults on the ...
Страница 4: ...ight Marking and intended use CAUTION Not intended for use in these conditions Where mud may be present on helidecks underground direct sunlight heavy vibrations high risk of impact harsh cleaning agents high pressure washer etc CE marking Other markings For use in safe area ...
Страница 5: ... lexan Input voltage 24 VAC VDC 100 230 VAC 50 60 Hz Light output Red 32 Candela Green 30 Candela Power consumption Max 10W Ingress Protection IP66 IP67 if drainplug is replaced with blind plug Entries Cable Glands 1xM25 stopping plug 1xM25 cable gland For use in zone Safe Area Height Red 240 mm Green 147 mm Width 140 mm Length 164 mm Weight Red 2 0 kg Green 1 9 kg Product description Perimeter li...
Страница 6: ...The included cable gland kit has two sealing rings included One for Ø11 0 15 0 mm and one for Ø15 0 20 1 mm cable Cables should have a bend downwards before entering the cable gland which will avoid water intrusion into the luminaire Secure the cable at a distance of maximum 50 cm from the luminaire Tighten the cable gland sealing pressure nut according to the specification of the cable gland o Ti...
Страница 7: ...sket is clean and properly aligned around the bottom of the globe assembly Carefully position the globe onto the lamp body and ensure that no wires is located between the lamp body and the globe assembly Place the globe ring over the globe and ensure the four screws enter the recessed nuts in the lamp body Slightly tighten the screws in a cross pattern to ensure that the globe lies straight and th...
Страница 8: ...Installation and operating manual TUM1072 TEF 2440 Perimeter Obstruction light Dimensions External dimensions ...
Страница 9: ...mplete connection assembly 4246 Cable gland E xe E204 622 M25 D Kit 11 0 20 1 mm 9mm brass 6222502 Stopping plug E xe TEF 794 650 M25 9mm Brass 6502500 Maintenance and cleaning Clean only with a damp cloth water and mild detergents Avoid chemicals with high or low pH abrasives high pressure washer strong detergents solvents petroleum or alcohol based cleaning agents and similar Avoid any corrosive...
Страница 10: ...Installation and operating manual TUM1072 TEF 2440 Perimeter Obstruction light Compliance Conformity Complies with ICAO Annex 14 Vol II Low type complies with IMO on 150mm height restrictions of IMO ...