TRAK VMC Mills with ProtoTRAK RMX CNC Safety, Installation, Maintenance, Service & Parts List
Maintenance
Time Period
Items
Daily
1.
Drain the water from the air regulator assembly by either turning off the air to
the machine or depressing the valve at the bottom of the water collector tank.
2.
Check to make sure there are no obvious oil leaks to the lubrication system.
3.
Check coolant level.
Weekly
1.
Check the level of the lubrication pump.
2.
Check the oil level in the oiler that supplies oil to the pneumatic components.
Month(s)
1.
Check the oil level of the Tool Change Air Cylinder Oil Cup, which is found under
the sheet metal that surrounds the head. You can view this oil cup when the
sheet metal is on by looking down from above.
2.
Every few months we recommend you remove the coolant tank and clean all
debris and replace the coolant.
3.
Remove the air filters in the electrical cabinet every few months and clean.
4.
Check the level and tram of the machine every 6 months and adjust as
necessary.
5.
Check the spindle motor belt tension every 6 months.
Yearly
1.
Check backlash on each axis and adjust as necessary.
2.
Remove all covers and clean chips and debris that may have built up.
3.
Inspect the ATC by removing the covers
4.
Inspect the tool change air cylinder
5.
Apply grease to the grease fittings on the ATC unit.
5.3
Laser Calibration
5.3.1 Accuracy
Your ProtoTRAK VMC is calibrated before it is shipped out to you using a highly accurate laser
interferometer system. It is calibrated over 25mm increments along the length of each ballscrew, and
saved onto a table within service code 123. We highly recommend creating your own backup onto a USB
flash drive using service code 142, in the event that you need to replace your computer in the future. If
needed, you can also contact us and we can email you the file from the time it was inspected.
5.3.2 Code 123: Calibration
From the main ProtoTRAK screen, go into SETUP, SERV CODES, CODE #, then type in 123 and press ABS
SET. This will bring up the calibration page.