62
TRAK Machine Tools
Southwestern Industries, Inc.
TRAK VMC Mills with ProtoTRAK RMX CNC Safety, Installation, Maintenance, Service & Parts List
Error
Number
Error Message
139
The ATC carrier is trying to move but the air pressure is too low. Check air pressure and
make sure it is set to the correct amount. If you were mid tool change when this error
occurred, then use service code 513 to reset the ATC.
143
The ATC carousel received a false trigger from the counter sensor. Check that the
counter sensor is clean of debris, then try re-homing the ATC using service code 513. See
Section 4.4.2
144
The ATC counter sensor is detecting that the carousel is not in location properly. Please
use code 513 to reset the ATC. If problem persists, check that the carousel is in location
properly, and that the ATC counter sensor is functioning properly. See Section 4.4.2
150
System has timed out waiting for the ATC Counter Sensor to change state. Confirm that
ATC Carousel is moving. Then check to make sure that the ATC Counter Sensor is free of
any oil or debris and retry. Use code 513 to reset the ATC. See Section 4.4.2
208
ATC limit switch failure. Both ATC IN and OUT limit switches are active. Check that both
ATC limit switches are functioning properly. If ATC was mid tool change when this error
occurs, then use service code 513 to reset the ATC.
218
The ATC timed out moving OUT to the stored location. Check the air pressure and the
ATC limit switches. If ATC was mid tool change when this error occurs, then use service
code 513 to reset the ATC.