![Tractel Tirak Blocstop BSO XE 1020 P Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/tractel/tirak-blocstop-bso-xe-1020-p/tirak-blocstop-bso-xe-1020-p_instruction-manual_1147520010.webp)
10
Figure 8
Hoist mounting
tirak
™
X-series
Figure 9
Hoist mounting
tirak
™
T-series
90°
Anchor
pin
Figure 11 Dimensions of connecting parts
tirak
™
T-series
Stirrup
90°
Stirrup
adapter
NOTE: Any rigging ar-
rangement other
than described
in this manual is
entirely under the
rigger’s respon-
sibility.
For special projects
like
shown in this
fi
gure
contact
the supplier for additional
information.
Figure 12 Special rigging arrangement
a
b
b
Ø d
e
f
a
1
a
3
Ø d
b
e
f
a
3
a
2
XE 301 P
Anchor pin Ø:
0.63 in. / 16 mm
Anchor hole Ø:
0.65 in. / 16.5 mm
a = 1.1 in. / 28 mm
b = 0.55 in. / 14 mm
c = 0.47 in. / 12 mm
d = 0.51 in. / 13 mm
e = 1.36 in. / 32 mm
f = 1.02 in. / 26 mm
a
1
= 4.41 in. / 112 mm
a
2
= 3.94 in. / 100 mm
a
3
= 3.86 in. / 98 mm
b = 1.58 in. / 40 mm
c
c
b
XE 500/600/700/1000
series
3.3 Hoist Mounting
3.3.1 tirak
™
X-series
Bolt the hoist to platform stirrup using
stirrup adapter
, which also holds
the hoist in its upright position (see
Figs. 8 and 10).
Use two 1/2 inch diameter grade 5 or
better bolts with locking nuts.
WARNING:
HOIST CONNECTION
BOLTS MUST NOT
BEAR ON THREADS.
3.3.2 tirak
™
T-series
Fix the hoist using its
anchor pin
(see Fig. 9 and 11). Make sure that
the hoist is held in its upright position
by means of an appropriate support.
The anchoring device must attach to
the pin between the 2 cast ears “b”
of Fig. 11.
Figure 10 Dimensions of connecting parts (stirrup adapter)
tirak
™
X-series
WARNING:
THE HOIST MUST BE MOUNTED SUCH
THAT THE WIRE ROPE PERPENDICU-
LARLY ENTERS THE HOIST.
(Figs. 8 and 9)
90°
XE 301 P