background image

 
TU600-X 
 

 

 

 

 

 

 

 

Corporate Office 
 

Trackunit A/S 
Gasvaerksvej 24, 4 sal 
9000 Aalborg 
Denmark. 

www.trackunit.com

 

 

Copyright and Trademarks 

© 1998-2019, Trackunit A/S. All rights reserved.  
Trackunit, Trackunit logo and Trackunit are trademarks of 
Trackunit A/S, registered in the United States and in other 
countries. All other trademarks are the property of their 
respective owners.  
 

Release Notice 

This document is release 1.0 of the TU600-X, Technical 
Manual. 
 

THIS MANUAL IS INTENDED FOR USE BY SYSTEM 

INTEGRATORS, SERVICE PROVIDERS AND APPLICATION 
DEVELOPERS (COLLECTIVELY, “RESELLERS”). IT IS NOT 

INTENDED FOR END-USERS OF THE TU600-X. ANY END-
USER DOCUMENTATION IS TO BE PREPARED AND 
FURNISHED BY THE RESELLERS. 

 
The following Product Limited Warranty gives Resellers 
specific legal rights. You may have others, which vary from 
state/jurisdiction to state/jurisdiction. 
 

Product Limited Warranty 

Subject to the terms and conditions set forth herein, Trackunit 
A/S (

“Trackunit”

) makes the following warranty only to its 

Resellers who purchase the TU600-X hardware product 
(

“Product”

) directly from Trackunit: for a period of one (1) 

year from the date of shipment from Trackunit, the Product will 
substantially conform to Trackunit’s standard published 
specifications for the Product and the Product hardware will be 
substantially free from defects in materials and workmanship. 
The foregoing warranty shall not apply to embedded 
software/firmware components. 
 

THIS PRODUCT LIMITED WARRANTY IS PROVIDED TO 
RESELLERS AND TO RESELLERS ONLY.  RESELLER IS 

SOLELY RESPONSIBLE FOR ANY AND ALL WARRANTIES 
MADE TO ITS CUSTOMERS, AND TRACKUNIT MAKES NO 

WARRANTIES, EXPRESS OR IMPLIED, AND SHALL HAVE 
NO OBLIGATIONS OR LIABILITY TO RESELLER’S 
CUSTOMERS OR END-USERS OF THE PRODUCT. 
RESELLER SHALL NOT 
MAKE ANY REPRESENTATIONS OR WARRANTIES ON 
TRACKUNIT’S BEHALF, AND SHALL FULLY INDEMNIFY, 
DEFEND AND HOLD TRACKUNIT HARMLESS FROM ANY 
BREACH OF THE FOREGOING. IF RESELLER DISTRIBUTES 
PRODUCT TO END-USER CUSTOMERS, RESELLER SHALL 

BE SOLELY RESPONSIBLE FOR PREPARING AND 
PROVIDING PRODUCT WARRANTIES AND PRODUCT 
LITERATURE TO END-USERS.

 

 
 

Warranty Remedies 

If the Product fails during the warranty period for reasons 
covered by this Product Limited Warranty and Reseller notifies 
Trackunit of such failure during the warranty period, Trackunit 
at is option will repair OR replace the nonconforming Product, 

OR refund the purchase price paid by Reseller for the Product, 
provided that Reseller returns the Product to Trackunit in 
accordance with Trackunit’s standard return material 
authorization procedures or as otherwise instructed by 
Trackunit. 
 

Warranty Exclusions and Disclaimers 

The foregoing Product Limited Warranty shall only apply in the 
event and to the extent that (i) the Product is properly and 
correctly installed, configured, interfaced, maintained, stored 
and operated in accordance with Trackunit’s specifications, and 
(ii) the Product is not modified or misused. This Product 
Limited Warranty shall not apply to, and Trackunit shall not be 
responsible for, defects or performance problems resulting from: 
(a) the combination or utilization of the Product with hardware 
or software products, information, data, systems, interfaces, 
services or devices not made, supplied or specified by 
Trackunit; (b) the operation of the Product under any 
specifications other than, or in addition to, Trackunit’s standard 
published specifications for the Product; (c) the unauthorized 
installation, modification or use of the Product; (d) damage 
caused by: accident, lightning or other electrical discharge, 
water immersion or spray, or exposure to environmental 
conditions for which the Product is not intended; or (e) normal 
wear and tear on consumable parts, including by way of 
example and without limitation, batteries. 
 

TRACKUNIT DOES NOT WARRANT OR GUARANTEE THE 
RESULTS OBTAINED THROUGH THE USE OF THE 
PRODUCT. THE FOREGOING TERMS OF THE PRODUCT 
LIMITED WARRANTY STATE TRACKUNIT’S ENTIRE 
LIABILITY, AND RESELLER’S EXCLUSIVE REMEDIES, 

RELATING TO THE USE AND PERFORMANCE OF THE 
PRODUCT EXCEPT AS OTHERWISE EXPRESSLY PROVIDED 
FOR IN THIS PRODUCT LIMITED WARRANTY, THE 
PRODUCT, ACCOMPANYING DOCUMENTATION AND 
MATERIALS, AND/OR ANY EMBEDDED 
SOFTWARE/FIRMWARE AND UPDATES THERETO ARE 
PROVIDED “AS-IS” AND WITHOUT EXPRESS OR IMPLIED 
WARRANTIES OF ANY KIND, BY EITHER TRACKUNIT OR 
ANYONE WHO HAS BEEN INVOLVED IN ITS CREATION, 

PRODUCTION, INSTALLATION OR DISTRIBUTION, 
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR 
A PARTICULAR PURPOSE, TITLE AND 
NONINFRINGEMENT. THE STATED EXPRESS 
WARRANTIES ARE IN LIEU OF ALL OBLIGATIONS OR 
LIABILITIES ON THE PART OF TRACKUNIT ARISING OUT 
OF, OR IN CONNECTION WITH, THE PRODUCT. 
WITHOUT LIMITING THE GENERALITY OF THE 
FOREGOING: 
TRACKUNIT IS NOT RESPONSIBLE FOR THE OPERATION 
OR FAILURE OF OPERATION OF GPS SATELLITES OR 
WIRELESS SERVICE OR THE AVAILABILITY OF GPS 
SATELLITE SIGNALS OR WIRELESS SERVICE. THE 
PRODUCT MAY CONTAIN TECHNOLOGY THAT IS NOT 
FAULT TOLERANT AND IS NOT DESIGNED, 
MANUFACTURED OR INTENDED FOR USE IN 
ENVIRONMENTS OR APPLICATIONS IN WHICH THE 
FAILURE OF THE PRODUCT WOULD LEAD TO DEATH, 
PERSONAL INJURY OR SEVERE PHYSICAL OR 
ENVIRONMENTAL DAMAGE OR SEVERE FINANCIAL LOSS. 

ANY USE OR DISTRIBUTION BY RESELLER OR ITS 
CUSTOMERS IN CONNECTION WITH ANY SUCH 

ENVIRONMENT OR APPLICATION SHALL BE AT 

Содержание TU600 Series

Страница 1: ...TU600 X TU600 X Technical Manual Version 1 0 December 2019...

Страница 2: ...Safety Information 11 Automatic battery safety during operation 11 Delivered standard content 12 Ready to Use No Custom Programming Required 12 Cost effective Universally Available Communications 12 U...

Страница 3: ...23 LTE M1 NB IOT WCDMA specifications 23 Mechanical specifications 25 Approvals and certificates 26 FCC and IC certification statements 26 Automotive off road vehicles machinery etc 27 EU regulations...

Страница 4: ...s or as otherwise instructed by Trackunit Warranty Exclusions and Disclaimers The foregoing Product Limited Warranty shall only apply in the event and to the extent that i the Product is properly and...

Страница 5: ...io communication However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which ca...

Страница 6: ...TU600 X Technical Manual v1 0 December 2019 Page 6 US and Canada certificates FCC ID ZMF TU600 IC 9746A TU600 EU certificate CE mark by EU Tec certificate T818625L 01 TEC Australia New Zealand SDOC a...

Страница 7: ...out the special features of this product Trackunit assumes that you are familiar with Microsoft Windows Related Information The Trackunit web site is found at www trackunit com This site links to the...

Страница 8: ...designs are compatible with the battery holder of the TU600 X There is risk of explosion or fire if an incorrect type replacement battery is forced into the battery holder as contact may generate a s...

Страница 9: ...the manufacturers of the medical devices to determine if they are adequately shielded from external RF energy Physicians may be able to assist in obtaining this information The TU600 X unit cannot be...

Страница 10: ...s fuel or chemical transfer or storage facilities vehicles using liquefied petroleum gas such as propane or butane areas where the air contains chemicals or particles such as grain dust or metal powde...

Страница 11: ...fety during operation For operational safety the battery inside the TU600 X is under constant environmental temperature control providing the following automatic battery safety The battery can only be...

Страница 12: ...ired Simply connect the unit to supply voltage 12V 24V 48V DC In its default configuration reports are sent nominally at 15 minute intervals or faster whenever there is motion Upon powering up the dev...

Страница 13: ...beneath metal parts To reduce hum and noise in the FM radio it is recommended to place the unit at a minimum distance of 20 inches 50 cm from the radio or the loudspeakers Installation for insurance a...

Страница 14: ...in case of a short circuit etc Digital inputs The activation of a digital input requires a minimum high level voltage of 9 5V Digital output The digital output has the type indication LO side switch...

Страница 15: ...operating hours To avoid this situation the digital input 4 Pink wire should be connected to the chassis ground on the machine Then send the following SMS to the unit phone number to activate the fil...

Страница 16: ...TU600 X Trackunit TU600 X Technical Manual v1 0 December 2019 Page 16 Functionality check...

Страница 17: ...kunit TU600 X Technical Manual v1 0 December 2019 Page 17 Verify my Trackunit In order to control if the installation of the TU600 X unit has been done correctly it is possible to use the Verify my Tr...

Страница 18: ...D in the unit is off thus no power on the unit Check if the installation is performed correctly according to the guidelines of this manual F3 The LED is constant red thus the unit is not attached to t...

Страница 19: ...age etc The current consumption of the relay must not exceed 200 mA DC current and the relay contacts must be specified to withstand the load that needs to be controlled NOTE The output can only handl...

Страница 20: ...Trackunit holds no liability for any damages occurred to persons vehicles moving machines construction machines etc caused by wrong installation and or faulty use of the digital output Warranty Tracku...

Страница 21: ...ax 30A i FKS blade fuse Max 80V 3A ATO style used with Littelfuse FH2 fuse holder Recommended Trackunit A S Gasvaerksvej 24 4 sal Dk 9000 Aalborg Tel 45 9973 0020 E mail support trackunit com Fax 45 9...

Страница 22: ...ns Operational voltage supply voltage 12 48 V DC Absolute maximum voltage range 8 58 V DC continuous Standby consumption GSM LTE M1 NB IOT receiver active 20 mA 10 mA average at 12V 24V Consumption du...

Страница 23: ...s from 40 C to 20 C or from 50 C to 70 C See internal temperature ranges for details 40 C to 70 C GSM GPRS specifications Supporting EGSM GPRS EGPRS 900 1800 850 1900 with maximum output power at EGSM...

Страница 24: ...l Manual v1 0 December 2019 Page 24 LTE TDD B39 B39 TX 1880 1920 MHz RX 1180 1920 MHz The marked bands B12 B13 are denoted LTE 700 MHz band lower and upper part The bands B18 B19 are denoted LTE 800 b...

Страница 25: ...al specifications Dimensions Length 122 1 mm Width 45 65 mm 49 mm incl mounting cradle Height 18 mm 23 mm incl mounting cradle Cable length 170 180 cm Environmental class IP68 Enclosure material Non f...

Страница 26: ...n le CFR 47 section 15 19 RSS GEN Le pr sent TU600 X appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux condition...

Страница 27: ...ehicles transients and radio spectrum and the council recommendation 1999 519 EC on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz when used as intended o T...

Страница 28: ...nese Radio Law This device should not be modified otherwise the granted designation number will become invalid Countries that are exempted for certification The TU601 x products can be placed on the m...

Страница 29: ...intended use of the product Standard Version Description A B SAEJ1455 2012 EN IEC 60068 2 1 2007 Cold SAEJ1455 2012 EN IEC 60068 2 2 2006 Dry Heat SAEJ1455 2012 EN IEC 60068 2 27 2010 Shock SAEJ1455 2...

Страница 30: ...TU600 X Trackunit TU600 X Technical Manual v1 0 December 2019 Page 30 Environmental protection without HW shield Environmental protection with use of HW shield...

Страница 31: ...d Declaration of conformity DOC statements can be downloaded from the Trackunit website http www trackunit com en trackunit approvals approvals htm PTCRB certification for interoperability with mobile...

Отзывы: