background image

TU600-X 

 

 

 
 

Trackunit TU600-X, Technical Manual v1.0, December 2019 

 Page 10 

Posted Facilities 

The TU600-X unit cannot be turned off after installation, so any vehicle, moving machinery, 
construction machinery installed with the TU600-X etc. must not enter any facility where posted 
notices prohibit the use of wireless phones or two-way radios. 

 

Aircrafts 

FCC and FAA regulations prohibit using wireless phones while in the air. Do not carry the TU600-X 
unit aboard an aircraft as it cannot be turned off. 

 

 

Potentially Explosive Atmospheres 

The TU600-X unit cannot be turned off after installation, so any vehicle, moving machinery, 
construction machinery installed with TU600-X etc. must not enter any area with a potentially 
explosive atmosphere and obey all signs and instructions. Sparks in such areas could cause an 
explosion or fire resulting in bodily injury or even death. 
 
Additionally, the TU600-X must not enter or in areas posted “turn off two-way radio” to avoid 
interfering with blasting operations. Obey all signs and instructions. 
 
Areas with a potentially explosive atmosphere are often, but not always marked clearly. Potential 
areas may include: fueling areas (such as gasoline stations); below deck on boats; fuel or chemical 
transfer or storage facilities; vehicles using liquefied petroleum gas (such as propane or butane); 
areas where the air contains chemicals or particles (such as grain, dust, or metal powders); and 
any other area where it would normally be advisable to turn off motor vehicle engines it is not 
allowed to enter with a vehicle, moving machinery, construction machinery installed with the 
TU600-X. 

 

For Vehicles Equipped with an Airbag 

An airbag inflates with great force. DO NOT place objects, including the TU600-X unit, in the area 
over the airbag or in the airbag deployment area. If in vehicle wireless equipment is improperly 
installed and the air bag inflates, serious injury could result. 

 

Specific Human Absorption Rates (SAR) 

THE TU600-X UNIT IS NOT DESIGNED TO BE WORN ON A PERSON’S BODY.  
AS SUCH, BODY WORN TEST POSITIONS FOR THE TU600-X UNIT  
ARE NOT REQUIRED BY EITHER THE IEC 62311 FOR GSM 900/1800 MHz BANDS, LTE 
M1/NB IOT 800/900/1800/2100 MHz BANDS OR FCC/IEEE/ICNIRP REQUIREMENTS FOR GSM 
850/1900 MHz BANDS, LTE M1/NB IOT 700/850/1700/1900 MHz bands. 
 
The TU600-X unit is not intended for handheld use or to be worn on the body. A minimum 
separation of ten (8”) inches (20 cm) is to be maintained between the TU600-X and any persons’ 
body. Additional information on Specific Absorption Rates (SAR) can be found on the Cellular 
Telecommunications & Internet Association (CTIA) Web site at 

www.ctia.org. 

 
 
 
 

Содержание TU600 Series

Страница 1: ...TU600 X TU600 X Technical Manual Version 1 0 December 2019...

Страница 2: ...Safety Information 11 Automatic battery safety during operation 11 Delivered standard content 12 Ready to Use No Custom Programming Required 12 Cost effective Universally Available Communications 12 U...

Страница 3: ...23 LTE M1 NB IOT WCDMA specifications 23 Mechanical specifications 25 Approvals and certificates 26 FCC and IC certification statements 26 Automotive off road vehicles machinery etc 27 EU regulations...

Страница 4: ...s or as otherwise instructed by Trackunit Warranty Exclusions and Disclaimers The foregoing Product Limited Warranty shall only apply in the event and to the extent that i the Product is properly and...

Страница 5: ...io communication However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which ca...

Страница 6: ...TU600 X Technical Manual v1 0 December 2019 Page 6 US and Canada certificates FCC ID ZMF TU600 IC 9746A TU600 EU certificate CE mark by EU Tec certificate T818625L 01 TEC Australia New Zealand SDOC a...

Страница 7: ...out the special features of this product Trackunit assumes that you are familiar with Microsoft Windows Related Information The Trackunit web site is found at www trackunit com This site links to the...

Страница 8: ...designs are compatible with the battery holder of the TU600 X There is risk of explosion or fire if an incorrect type replacement battery is forced into the battery holder as contact may generate a s...

Страница 9: ...the manufacturers of the medical devices to determine if they are adequately shielded from external RF energy Physicians may be able to assist in obtaining this information The TU600 X unit cannot be...

Страница 10: ...s fuel or chemical transfer or storage facilities vehicles using liquefied petroleum gas such as propane or butane areas where the air contains chemicals or particles such as grain dust or metal powde...

Страница 11: ...fety during operation For operational safety the battery inside the TU600 X is under constant environmental temperature control providing the following automatic battery safety The battery can only be...

Страница 12: ...ired Simply connect the unit to supply voltage 12V 24V 48V DC In its default configuration reports are sent nominally at 15 minute intervals or faster whenever there is motion Upon powering up the dev...

Страница 13: ...beneath metal parts To reduce hum and noise in the FM radio it is recommended to place the unit at a minimum distance of 20 inches 50 cm from the radio or the loudspeakers Installation for insurance a...

Страница 14: ...in case of a short circuit etc Digital inputs The activation of a digital input requires a minimum high level voltage of 9 5V Digital output The digital output has the type indication LO side switch...

Страница 15: ...operating hours To avoid this situation the digital input 4 Pink wire should be connected to the chassis ground on the machine Then send the following SMS to the unit phone number to activate the fil...

Страница 16: ...TU600 X Trackunit TU600 X Technical Manual v1 0 December 2019 Page 16 Functionality check...

Страница 17: ...kunit TU600 X Technical Manual v1 0 December 2019 Page 17 Verify my Trackunit In order to control if the installation of the TU600 X unit has been done correctly it is possible to use the Verify my Tr...

Страница 18: ...D in the unit is off thus no power on the unit Check if the installation is performed correctly according to the guidelines of this manual F3 The LED is constant red thus the unit is not attached to t...

Страница 19: ...age etc The current consumption of the relay must not exceed 200 mA DC current and the relay contacts must be specified to withstand the load that needs to be controlled NOTE The output can only handl...

Страница 20: ...Trackunit holds no liability for any damages occurred to persons vehicles moving machines construction machines etc caused by wrong installation and or faulty use of the digital output Warranty Tracku...

Страница 21: ...ax 30A i FKS blade fuse Max 80V 3A ATO style used with Littelfuse FH2 fuse holder Recommended Trackunit A S Gasvaerksvej 24 4 sal Dk 9000 Aalborg Tel 45 9973 0020 E mail support trackunit com Fax 45 9...

Страница 22: ...ns Operational voltage supply voltage 12 48 V DC Absolute maximum voltage range 8 58 V DC continuous Standby consumption GSM LTE M1 NB IOT receiver active 20 mA 10 mA average at 12V 24V Consumption du...

Страница 23: ...s from 40 C to 20 C or from 50 C to 70 C See internal temperature ranges for details 40 C to 70 C GSM GPRS specifications Supporting EGSM GPRS EGPRS 900 1800 850 1900 with maximum output power at EGSM...

Страница 24: ...l Manual v1 0 December 2019 Page 24 LTE TDD B39 B39 TX 1880 1920 MHz RX 1180 1920 MHz The marked bands B12 B13 are denoted LTE 700 MHz band lower and upper part The bands B18 B19 are denoted LTE 800 b...

Страница 25: ...al specifications Dimensions Length 122 1 mm Width 45 65 mm 49 mm incl mounting cradle Height 18 mm 23 mm incl mounting cradle Cable length 170 180 cm Environmental class IP68 Enclosure material Non f...

Страница 26: ...n le CFR 47 section 15 19 RSS GEN Le pr sent TU600 X appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux condition...

Страница 27: ...ehicles transients and radio spectrum and the council recommendation 1999 519 EC on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz when used as intended o T...

Страница 28: ...nese Radio Law This device should not be modified otherwise the granted designation number will become invalid Countries that are exempted for certification The TU601 x products can be placed on the m...

Страница 29: ...intended use of the product Standard Version Description A B SAEJ1455 2012 EN IEC 60068 2 1 2007 Cold SAEJ1455 2012 EN IEC 60068 2 2 2006 Dry Heat SAEJ1455 2012 EN IEC 60068 2 27 2010 Shock SAEJ1455 2...

Страница 30: ...TU600 X Trackunit TU600 X Technical Manual v1 0 December 2019 Page 30 Environmental protection without HW shield Environmental protection with use of HW shield...

Страница 31: ...d Declaration of conformity DOC statements can be downloaded from the Trackunit website http www trackunit com en trackunit approvals approvals htm PTCRB certification for interoperability with mobile...

Отзывы: