20 |
ANNEX A | INSTALLATION OF THE VACUUM BED
After unpacking the TQC automatic Film applicator the rubber seals for the vacuum bed need to be placed.
Without these seals the vacuum can NOT be created.
Remove all tape holding the perforated or double channel vacuum plate. Take great care to remove all the tape.
Remove the vacuum plate from the base plate, and stow it in a safe place.
Take the two black rubber rings from the package and differentiate in size.
Place the smallest of the rings (A4) around the inner supports and the largest (A3) around the outer supports, as
shown in below image (detail A).
Gently lower down the vacuum plate (B or C). Take care not to disturb the placement of the rubbers.
Turn the device on and follow the instruction to start a new test, using an A3 test chart, however hold at the step
where the vacuum pump turn on.
Place an A3 test chart and press it down. It should be sucked to the vacuum table. If not grab the sides of both
plates and press them together.
When the pitch of the vacuum pump changes and sounds softer the vacuum seal is complete.
Continue the run and afterwards you are ready.