41
The connector by the side of the VF66B inverter of the cable manufactured by the above-mentioned
is connected with connector CN1 of a VF66B inverter. When connecting a connector to a VF66B
inverter, a cable is taken in from the lower part of an inverter and it connects with connector CN1 for
communication in the inside of an inverter. (The positions of the connector for communication differ
depending on the model of a VF66B inverter. )
Insertion
Cable
VF66B inverter
(Capacity of 30kW or more)
CN1
CN1
Connection
Figure 7.10 Connection between DBIF2009-Z PC board and VF66 inverter
In the case of the parallel operation of DB unit
, the telecommunication cable which connects a
DBIF2009-Z board and a DBIF2009-Z board is required. The cable is not attached. Please manufacture
a connecting cable with reference to the parts of Table 7.4.
Table 7.3 Cable parts between DBIF2009-Z PC board and DBIF2009-Z PC board
Name
Type
Maker
Quantity Remarks
CN2 or CN3
(DBIF2009-Z side)
Housing
5051-04
Molex
1
Terminal
2759G
Molex
4
Gilding processing article
CN2 or CN3
(DBIF2009-Z side)
Housing
5051-04
Molex
1
Terminal
2759G
Molex
4
Gilding processing article
Cable
※
Cable
CO-SPEV-SB(A)
2Px0.5SQLF
Hitachi
cable
1
Recommendation
※
1
:
An equivalent article is also good for a cable. The line of a connector 1 and two pins and the line of 3
and 4 pins are made to twist, respectively.