Figure 32: Roof vent terminal.
VERTICAL TERMINATION CAP
(TCVT.9365)
FLASHING
STORM COLLAR
(TC42.90665)
MASTIC
NOTE: ADJUSTABLE FOR VARIOUS
ROOF PITCHES, FROM FLAT ROOF TO
12/12 PITCH ROOF.
VENT PIPE
Note:
Adjustable for various roof
pitches, from flat roof to 12/12
pitch roof.
Roof Vent Terminal:
1. Place the roof flashing over the vent pipe, secure and seal it to the roof using the methods and materials appro-
priate for the type of roof on the building. Shingle roof example shown (Figure 32).
2. Place the storm collar down over the vent pipe until it is level. Tighten storm collar for a snug fit. Apply a thick
horizontal ring of mastic around the pipe at top of the storm collar (Figure 32).
3. Lower the roof vent terminal cap over the vent pipe and secure in place with screws provided (Figure 32). Seal
screw heads and joints with caulking to prevent any moisture entering the venting system.