![Town & Country Fireplaces TCWS.54CODE Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/town-and-country-fireplaces/tcws-54code/tcws-54code_installation-and-operating-instructions-manual_1141215016.webp)
Honeywell Control Valve
Plumbing and Electrical
The gas control system is located on the right
hand side of the firebox behind an access panel
and the decorative firebox panel (if installed).
The fireplace is operated via a wall switch.
The wall control is connected to the fireplace by
a 14-2 AWG wire, not supplied with the fireplace.
Installation
1. Place the fireplace in the desired location.
2. Remove the window from the fireplace.
3. Remove access panel from right hand side
of the firebox (Figure 24).
4. Remove the cover from the electrical box
(Figure 25).
5. Run two 110 V. AC switched electrical sup-
plies to the control box and connect to the
terminal block installed inside the control
box (Figure 26). The fireplace operates on
24V AC supplied by a transformer rated at
110 volts, 60Hz. See wiring diagram on page
29 for correct connections on terminal block.
6. Connect the gas supply to the valve
(Figure 27).
ACCESS PANEL
Figure 24: Access panel location.
ELECTRICAL
BOX COVER
Figure 25: electrical box cover.
TERMINAL BLOCK,
ELECTRICAL
CONNECTIONS
Figure 26: Electrical connections.
GAS INLET
Figure 27: Gas inlet.
16
5055.5401-A
TCWS.54CODE_041115-36