5 7/8
18 3/4
101 3/4
71 3/4
72 1/8
35 1/4
24 3/8
w
MAXIMUM FACING DEPTH
18 3/4"
5"
NON-COMBUSTIBLE BOARD DETAIL
Fig. #9
Fig. #10
Fig. #11
NON-COMBUSTIBLE BOARD (OR
OTHER NON-COMBUSTIBLE
MATERIAL) MUST EXTEND 18
3/4" ABOVE AND 5" TO THE
SIDES OF THE FRAMING EDGES.
NON-COMBUSTIBLE BOARD
MINIMUM COMBUSTIBLE FRAMING DIMENSIONS
NOTE: FIREPLACE SHOULD BE IN ITS FINAL LOCATION BEFORE FRAMING.
NON-COMBUSTIBLE RECESSED
INSTALLATION DETAIL
STEEL STUDS
NON-COMBUSTIBLE
MATERIAL
NON-COMBUSTIBLE
BOARD
INCLUDING SHEET ROCK
Fig. #9a
IT IS RECOMMENDED TO USE FULL
SHEETS OF CALCIUM SILICATE
BOARD OR ITS EQUIVALENT AND
FULL LENGTH METAL STUDS TO
FINISH AND FRAME AROUND THE
UNIT.
FOLLOW THE MANUFACTURERS
MOUNTING AND FINISHING IN-
STRUCTIONS CLOSELY.
NON-COMBUSTIBLE
BOARD
9
TC54.CE3 220313-40