61 1/8"
35 1/2"
53 9/16"
31 1/4"
* MANTEL CLEARANCE
A
17”
B
15”
C
12”
** MANTEL DEPTH
D
12”
E
6”
F
1”
MANTEL CLEARANCE
CHART
NOTE:
To ensure that the
hearth does not
interfere with the
window frame, the
fireplace must be
raised.
Refer to
‘Hearth Extension’
section for details.
Minimum Clearances:
Side standoffs ........................................ 0 in. (0 mm)
Back standoffs ....................................... 0 in.
(0 mm)
Top standoffs ......................................... 0 in.
(0 mm)
Bottom of appliance ............................... 0 in.
(0 mm)
Adjacent side wall .................................. 4 in.
(102 mm)
Ceiling to appliance ............................. 24 in.
(610 mm)
*Mantel to appliance ................... See Fig.#2
**Maximum Mantel extension ..... See Fig.#2
Mantel support ....................................... 4 in.
(102 mm)
Vertical vent pipe ...........................1 3/4" in.
(45 mm)
Horizontal Vent pipe
(Top, sides and bottom) ..................1 3/4" in.
(45 mm)
Fig. #3
24”
4”
MANTEL
ADJACENT WALL
OR MANTEL SUPPORT
CEILING
A 18" DEEP, 2" THICK, NON-COMBUSTIBLE HEARTH MUST
BE PLACED IN FRONT OF THE FULL WIDTH OF THE GLASS
*
**
Fig. #1
16 3/16”
48 1/8”
15 3/4”
63 7/8”
44 1/8”
53 9/16”
61 1/8"
53 9/16"
35 1/2"
30 15/16"
Fig. #2
MAY USE COMBUSTIBLE
FACING MATERIAL IN THIS AREA
NON-COMBUSTIBLE
FINISH MATERIAL
SEE FIG #8 & #9
NON-COMBUSTIBLE ZONE.
DO NOT INSTALL ANY COMBUSTIBLE MATERI-
AL, ELECTRICAL WIRING OR GAS PLUMBING IN
THIS AREA.
COMBUSTIBLE FRAMING AND
FINISH WALL ABOVE STANDOFFS
STANDOFFS
STEEL FRAMING
FIREPLACE FRONT
TOP OF LINTEL BAR
A
B
C
D
E
F
43 5/8”
30 15/16"
5
TC54.CE3 220313-40
Fireplace Dimensions
Minimum Clearances to Combustible Material