TC36STD2
Figure 34: TC36ST Wall vent terminal framing.
Vent pipe:
Install vent pipe through the wall thimble and attach to flue outlet collar on top of the fireplace. Secure all joints with
screws and seal with approved "High Temp." self-adhesive aluminum tape provided. See Figure 42 on page 27.
Adjust the fireplace position so that the vent pipe does not protrude beyond the outer wall. The vent connector on the
termination will accommodate walls up to 12" thick.
Wall vent terminal:
1. Engage the terminal with the vent pipe and slide terminal into place. Ensure that both inner and outer pipes are fully
engaged and then attach the terminal to the outside wall. The vent terminal must not be recessed into the exterior
wall or siding.
2. Caulk in place to prevent any moisture entering the building.
NOTE: MINIMUM CLEARANCES TO THE VENT TERMINAL MUST BE MAINTAINED, See Figure 41 & Figure 42 on
page 27.
HORIZONTAL
TERMINAL
TCVT.9360
14 1/2" FRAMED
OPENING
WALL SHIELD THIMBLE
TCVT.THIMA
ELBOW
TCVT.811XLB90
*
24"
VENT PIPE
TCVT.811X24
12" VENT PIPE
TCVT.811X12
* Minimum height from the floor to center of the opening with a maximum
horizontal run of 32 1/2" from the center of the flue outlet to the outside face of
the outer wall. The height will need to be increased with longer horizontal pipe.
21
100000438-50 091418-41