TC36STD2
17
100000438-50 091418-41
Figure 29: Complete communication
wiring.
to home
automation
system
NOTE:
When a signal has been supplied by the home automation system, the fireplace control
will repeat the signal every 2 hours or until a new command has been received.
The home automation feature supplied with this fireplace is capable
of controlling the flame and light on/off function with the use of a dry
contact relay common to home automation systems. Furthermore, the
flame and light level may be modulated from high to low using the
0 - 10 volt analog output available on most home automation
systems.
(Figure 30) shows the wire designations required to connect the
fireplace to a home automation system.
Home Automation
Note: Leave the wall switch on the “Remote” setting when using
home automation.
NOTE:
• Digital I/O must be connected to a dry contact relay.
• Analog flame and light input through 0 - 10 volt DC signal scaled
as follows:
Low = 1 volt
High = 10 volts
Figure 30: Home automation wiring diagram.