Figure 42: TC36ST Sealing vent joints.
All outer joints of the vent pipe must be sealed with the approved "High
Temperature" self-adhesive aluminium tape provided. Wrap the tape
completely around the joint and press firmly in place.
APPROVED “HIGH TEMP.”
SELF-ADHESIVE TAPE
VENT PIPE
TC36STD2
^ a vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*
** only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the floor*
* as specified in CGA B149 Installation Codes, Note: local Codes or Regulation may require different clearances
* for U.S.A. Installations follow the current National Fuel Gas Code, ANSI Z223.1
Figure 41: Vent terminal minimum clearances.
27
100000438-50 091418-41
Vent Pipe Sealant