![Town & Country Fireplaces Architectural Series Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/town-and-country-fireplaces/architectural-series/architectural-series_installation-manual_1141151027.webp)
23”
Site Fabricated
Mounting Curb
12
1/2
” Min.
23”
12
1/2
” Min.
Max 22
1/2
”
Max 22
1/2
”
2
1/2
”
Figure 22: Power vent horizontal installation.
When installing the power vent horizontally, ensure the side of the power vent with the
attached electrical junction box is facing downwards.
Use exterior silicone/caulk around the base of the power vent to seal it to the building
envelope.
Any horizontal run leading to the power vent shall be sloped down to the outside at a
minimum of 1/4 inch per foot of vent length.
Horizontal Installation
27
031220-60 Architectural Series
100004782