NOTE:
The architectural
series fireplaces with the
exception of the peninsula
models are capable of
bearing up to 1000lbs of
facing material weight. Up
to 1 inch stone may be
used. An architectural series
fireplace is not to be used
as a load bearing structure.
Channels will
accommodate
1/2” Drywall or
Facing Material
Figure 11: Leading edge of drywall.
Facing Material
Because the unit requires no clearance to combustible material, drywall or other facing material can
be affixed directly to the surface of the unit. Using standard 2x4’s and 2x6’s in the framing process
allows for the edge of 1/2” drywall or other facing material to fit into the channels which make up the
perimeter of the exterior glass sheets (Figure 11 and Figure 12).
To Power Vent
1/2” Drywall or
Facing Material
1/2” Drywall or
Facing Material
2X4” Studs
2X6” Studs
Optional site
fabricated platform
Figure 12: Right side framing and facing view.