tousek
/ E_SWING-225_42200116 / 30. 03. 2011
- 5 -
Mounting measures SWING 225/29
opening to the INSIDE
Application
standard
dimensions for
max.
opening angle
leaf width max. up to
2,5m
A (mm)
130
110
B (mm)
130
120
C (mm)
900
900
D (mm)
100
95
max. opening angle
90°
110°
Mounting measures
SWING-225 AEB
ope-
ning to the OUTSIDE
225 AEB/29
225 NB/29
leaf width max. up to
1,8m
2,5m
A (mm)
125
B (mm)
125
C (mm)
630
D (mm)
110
max. opening angle
95°
Note
• In this special case where a type 265 operator is installed
on the inside of an outside swinging gate leaf, the version
225 AEB can be used up to a gate leaf width of 1.8 m.
On wider gate wings the 225 NB version has to be used,
and an additional electric lock has to be installed.
•
Furthermore, the rear connecting bracket has to be very
strong or supported in order to limit vibrations
Opening to the INSIDE
(Center of rotation in line with center axis of gate wing)
•
profile strength max. 60mm
Opening to the INSIDE
(Center of rotation not in line with center)
Mounting measures with different swing gate installations
Special case: opening to the OUTSIDE
NOTE
• On existing larger gate columns the operator series
265/44 can be used.
• On larger gate columns it may be necessary to make
a recess (N) in order to achieve the dimensions A and
B.
Note: The recess in the gate column has to be
big enough to make sure that the electrical supply
cable of the operator will not be
Installation on larger pillars
A
B
C
D
INSIDE
N
ca.100
ca.150
ca.250
A
B
C
INSIDE
D
A
B
C
OUTSIDE
D
A
B
C
INSIDE
D