- 24 -
tousek
/ EN_ST-80A_04 / 25. 03. 2020
Important
•
The optional module „Status display“ has to be plugged onto the connector slot (ZM) of control board and
enables the evaluation of boom position or boom movement.
•
Function of module: depending on the adjustments under „Peripherals / Signal contacts“
(p. 21)
.
Connection the module
• Turn off the power supply !
• Plug in the „status display“ module into the
slot
(ZM)
.
• With the potential free signal contacts K1 (term. 90/91) and K2 (term. 92/93) the barrier status can be evaluated in
two ways
(see menu point about signal contacts)
.
• Contact load:
24Va.c./d.c., max. 10W
5. Status display module
(optional)
Barrier control board
ST 80(V)A
90 91 92 93
Signal contact
K1
Signal contact
K2
ZM
ST 80(V)A