tousek
/ EN_ST-61A_08 / 25. 03. 2020
- 25 -
Electric lock
Electric lock module, page 26
Peripherals
switched off
1–10s adjustable:
The electric lock is activated by push button impulse or impulse from pedestrian button for a
period of time set here to ensure the release depending on the gate situation
Reverse stroke
(only with activated locking!)
Peripherals
switched off
0,5–8s adjustable:
Only with activated lock (electric lock or motorized locking bar): After an impulse is given, a short
closing movement for unlocking (for example, the E-lock) is initiated first, the unlocking is performed and the door is
opening. With an electric lock, the reversal stroke is only carried out in the opening direction. With a motor bolt, depend-
ing on the setting, it is possible to set the reversal stroke also in the closing movement.
Additional module
Peripherals
courtyard/control lamp:
the menu points courtyard lamp and control lamp are ready for adjustment (that means if not
selected, these menu points will not be shown on the display)
status display 1:
with the two potential-free signal contacts K1 and K2, the gate end positions (limits) can be
evaluated.
status display 2:
with the two potential-free signal contacts K1 and K2, the gate end positions (limits), the gate mo-
vement as well as a gate stop outside of the end positions can be evaluated.
Additional module (optional)
•
turn off power supply before installing the additional module!
• Depending on which device, e.g. a
courtyard-/Control lamp
is
chosen or
evaluation of gate status
should be effected, the corresponding
module
(Z)
has to be plugged to the according slot/plug
(ZM)
of control board.
• Additionally the corresponding value has to be selected in menu point
„Additional module“.
Additional module
Courtyard lamp/
Control lamp
• On the terminals 12/13
a courtyard lamp (H)
can be connected:
230V, max. 100W
• On the terminals 70/71
a control lamp (K) can
be connected:
24Vd.c., max. 2W
12 13 70 71
L N
H
K
– +
Additional module
Gate status display
• with potential free signal contacts K1 (Kl.
90/91) and K2 (Kl. 92/93) the gate staturs
can be evaluated in two ways (see menu
point „Additional module“).
• Contact load:
24Va.c./d.c., max. 10W
Function
K1 K2
Gate status display
1
Gate in CLOSE-Position
1
0
Gate in OPEN-Position
0
1
2
Gate in CLOSE-Position
0
0
Gate opens or closes
0
1
Gate stopped or fault
(Gate not in end position)
1
0
Gate in OPEN-position
1
1
signal contacts: 0 = open, 1= closed
90 91 92 93
signal contacts
K1
K2
ZM
Z
ZM
ST 61A
Locking
Peripherals
e-lock/magnetic clamp:
with additional module electric lock/magnetic clamp.
motor lock:
with additional module motorized locking bar.
Motor lock
Motor lock module page, 26
Peripherals
OPEN and CLOSE:
locking via motorized locking bar in both end positions of the gate.
only OPEN:
locking via motorized locking bar only in open position.
only CLOSE:
locking via motorized locking bar only in closed position.
Peripherals
Connections and adjustments