- 10 -
tousek
/ EN_PULL-T8-T10-T15-M-S_02 / 25. 03. 2020
Slave control unit
Terminal assignment
40
41
43
45
46
31
37
32
30
33
34
52
51
50
1
2
10
11
85
84
86
L
N
8.k2
8.k2
L
N
black
Motor connection
ret
230V
a.c.
blue
pre-wired
Motor condenser
Signal lamp 230V, 100W
Power supply 230V a.c.
Main safety sensing edge
Side safety sensing edge
common contact safety edge
Jumper (must not be removed!)
Power supply
max. 24Va.c., 5W
Grounding
The grounding connection is made on the operator
housing with the designated grounding screw!
see figure page 8
• During connection, adjustment and maintenance works please take care, that the electronic circuit
board won´t be damaged by moisture (rain).
Connection Master /Slave control unit
•
For the connection of the master and slave control unit connect the
terminals 88 and 89 in the system connector to each other.
•
Max. cable length between the operators: 25m.
•
Cable type e.g.: PVC control cable YSLY 2 x1mm
2
or equivalent.
Safety sensing edges
Function main safety sensing edge (MCE):
Safety during closing
Function side safety sensing edges (SE):
Safety during opening
MCE
SE
CLOSE OPEN
88
89
B
MASTER control unit
88
89
B
High
Low
Bussystem