Mute Control Button
The alarm can be muted for up to 10 minutes while trouble shooting is conducted. After 10 minutes,
if the fault has not been rectified, the alarm will reactivate.
• To mute the alarm, press the Alarm Mute Button this is confirmed with a single Beep.
Alarms and Alerts
The Toto Touch Control Unit has five integrated system error indicators
System Error Indicators
Indicated by an audible beep and:
Low system pressure
Pressure in the system has fallen below the minimum
operational requirements.
Five ‘Rest time LEDs’ flashing (when activated).
High system pressure
Air flow between the Control Unit and platform is
prevented.
Five ‘Inflate time LEDs’ flashing (when activated).
Service interval
Service required default at one-year use.
Service LED permanently lit amber
(No audible alarm).
Power Failure
Power to the Control Unit has been interrupted.
Audible beep, no LED lit.
Initialisation Failure
Control unit fails to start.
Five ‘Inflate time LEDs’ and Five ‘Rest time LEDs’
flashing (when activated).