Warranty

The Toto lateral turning system warranty is valid for one year from time of shipping. If a 
defect or fault is discovered, please contact Frontier Therapeutics Ltd Customer Services on  
Tel: +44 (0) 1495 235800 or email: [email protected] immediately.

Frontier Therapeutics Ltd guarantees the equipment is free from defects in material and 
workmanship, under normal use and service.

During the warranty period, any product that has become defective due to faulty workmanship or 
material will be replaced as deemed appropriate by Frontier Therapeutics Ltd, without charge for 
parts or labour. During this time, a loaned Control Unit will be made available if required.

If the product is damaged due to an accident, negligence or misuse, the product warranty will be 
forfeited. No unauthorised alterations are permitted. Both warranty and fire retardancy certification 
will be null and void if non-Frontier Therapeutics Ltd spares or replacement parts are used.

Frontier Therapeutics Ltd will not accept responsibility for damage caused by misuse, negligence, 
accidental damage nor non-observance of the instruction set out within this document. This 
warranty does not affect your statutory rights.

Fire Testing

The Toto lateral turning system platform meets the requirements of ‘The Furniture & Furnishings 
(Fire) (Safety) Regulations 1988’. Meeting the requirements of BS 7175: 2008 for medium hazards.

Standards and Regulation

This Active Class II Device complies with the requirements of the MDD 93/42/EEC (as amended).

The Control Unit is tested to EC Directive 2004/108/EEC and EN 55011.

Other Standards

ISO 9001:2015 Quality Management Systems

ISO 13485:2016 Medical Devices - Quality Management Systems

No modification of this equipment is allowed.

Technical Specification

Toto Touch Technical Specifications

Power input - Europe

AC 220 - 240VAC 50Hz, 0.2A

Power input - USA

AC 100 - 120VAC 60Hz, 0.3A

Fuse rating

T1AL250V

Compressor

SAA-1

Air distributor

Timing motor working as rotary valve

Control system

Digital control system

Power consumption  

14 Watt (typical) / 20 Watt (maximum)

Operation mode

Non-continuous

Cycle control

Distributor valve supplying air to the inflatable cells

Cycle time

Adjustable 30 > 240 minutes

Pressure setting

120mmHg ± 10mmHg

Piping output

2

Max. load on platform

190Kg

Operating environment

Air humidity 30% to 70% 
Ambient temperature 10ºC to 40ºC Altitude ≤ 2000m

Storage/Transportation

Environment air humidity 10% to 70% 
Ambient temperature -10°C to 60°C Altitude ≤ 2000m

Classification

Class II equipment 
Type B applied part 
IP44

Содержание GP0133-A50-01

Страница 1: ...Toto Lateral Turning System with Toto Touch Control Unit User Guide www frontier group co uk...

Страница 2: ...wed Do not pierce or cut Do not iron Line dry Refer to user manual CE Compliant Type BF applied part Keep dry Class II equipment Disposal do not dispose of this product as unsorted domestic waste It m...

Страница 3: ...lease Pull Tag 45 XL 35 1 4 271 11 Quick Release Pull Tag 30 Product Weight kg lbs Maximum User Weight kg lbs Width mm Inches Length mm Inches Standard 18 40 190 419 745 29 1850 73 45 18 40 190 419 74...

Страница 4: ...es or pillows etc Intended Care Setting Toto Lateral turning system is intended to be used in the following care settings Long term or extended care such as nursing homes and care homes Home care Hosp...

Страница 5: ...the Control Unit Black to Control Unit ensuring the hoses are not twisted or kinked F 10 Connect the Control Unit to the mains power via the cable supplied G A The platform should be placed directly o...

Страница 6: ...d hold the start stop button for 3 seconds A single beep will confirm activation and the start stop green LED will be lit Note the system default setting will automatically be selected o Air cell infl...

Страница 7: ...utton a single beep will confirm activation The start stop LED will flash when active and all other LED s will turn off After 10 minutes in Therapy Pause Mode the alarm will sound To continue in this...

Страница 8: ...dible beep and Low system pressure Pressure in the system has fallen below the minimum operational requirements Five Rest time LEDs flashing when activated High system pressure Air flow between the Co...

Страница 9: ...ion even though the service LED remains lit Interface panel is lit but unresponsive Interface panel is locked Press and hold ALARM MUTE button for 4 seconds Audible beep no LEDs lit Accidental removal...

Страница 10: ...on and feed air cell hoses through apertures at the bottom of the cover 8 Reattach the hoses using the quick connectors Red to Red ensuring they are not twisted or kinked Disposal IMPORTANT In order t...

Страница 11: ...n may be achieved by laundering at temperatures not exceeding 65 C for 10 minutes or 73 C for three minutes 1 1 Protect Rinse and Dry BHTA guidance on the care cleaning and inspection of healthcare ma...

Страница 12: ...ot affect your statutory rights Fire Testing The Toto lateral turning system platform meets the requirements of The Furniture Furnishings Fire Safety Regulations 1988 Meeting the requirements of BS 71...

Страница 13: ...rk of Frontier Therapeutics Ltd November 2017 Frontier Therapeutics Limited All rights reserved GP0133_A50_01 w ww your turn org u k Frontier Therapeutics Limited Newbridge Road Industrial Estate Blac...

Отзывы: