Toto EcoPower Axiom Скачать руководство пользователя страница 9

10

ENGLISH

TROUBLESHOOTING

Problem

Cause

Solution

Water won’t begin 

running.

The surface of the sensor is dirty. 

Clean the surface of the sensor.

There is an obstruction in front of the sensor.

Remove the obstruction.

The stop valve is turned off. 

Turn on the valve.

Backup battery connector is disconnected. 

Connect the backup battery connector.

The power generator and sensor connector is disconnected.

Securely attach the connector(s).

Water supply is suspended.

Wait until the water supply is restored.

The strainer or the regulating screen is clogged.

Clean the strainer and the regulating screen.

Water won’t stop 

running. 

The surface of the sensor is dirty. 

Clean the surface of the sensor.

There is an obstruction in front of the sensor.

Remove the obstruction.

If the water continues to run after attempting the above solutions, turn off the stop valve. 

Low fl ow rate.

The stop valve is not fully opened.

Open the stop valve fully.

The strainer or the regulating screen is clogged.

Clean the strainer and the regulating screen.

Water temperature 

is too high.

The temperature control handle is set at “H”.

Set the temperature control handle to the middle point. 

The stop valve connected to the cold-water supply is not fully 
opened.

Open the cold-water stop valve fully. 

Water temperature 

is too low. 

The temperature control handle is set at “C”. 

Set the temperature control handle to the middle point. 

The stop valve connected to the hot water supply is not fully 
opened.

Open the hot water stop valve fully.

The hot water supply temperature is lower than 120°F.

Set the hot water supply temperature to 120°F.

Water temperature 

is not controlled 

properly.

One side of the stop valve is not fully opened.

Open the stop valve fully.

The strainer or the regulating screen is clogged.

Clean the strainer and the regulating screen.

Short detection 

range. 

The self-adjusting sensor may not work properly when strained 
or blocked by water droplets.

Clean the sensor surface. 

SPECIFICATIONS

Power supply

Hydropower Generation

Sensor Detection Range

5-1/8’”~ 7-7/8” (130~200mm) 

Sensor is self-adjusting. 

Water Supply Pressure

Minimum required water pressure: 15 psi (100 kPa) (Flowing)

Maximum water pressure: 80 psi (551 kPa)

Water Supply Connection

1/2” NPSM

3/8” Compression (for Integrated Faucets only)

Inlet Temperature range

HOT: 120~180**°F (49~82°C)

COLD: 39~80°F (4~27°C)

Ambient Temperature

32~104°F (0~40°C)

Humidity

Max. 90% RH

Flow Rate*

VARIED : 1.06 gallon per minute (4 L/min.), 0.8 gallon per minute (3 L/min.) and

0.5 gallon per minute (2 L/min.)

TEL5LI15 MODEL: minimum fl ow rate: 0.46 gpm (1.74 lpm)

water consumption: 0.15 gallon/cycle

Duration Time of Water Discharge*

10 seconds
15 seconds
60 seconds

*Refer to Price Book or consult with a TOTO Rep. for model numbers, fl ow rate and water discharge duration of each model.
**Check your local plumbing codes.

Содержание EcoPower Axiom

Страница 1: ...atic Faucets Grifos Autom ticos EcoPower Robinets Automatiques EcoPower NOTE ASSE1070 supercedes ASSE1016 for non shower point of use devices Applies to TEL5 series models NSF ANSI 61 9 applies to all...

Страница 2: ...d Integrated FordhamTM AxiomTM RyohanTM Gooseneck Gooseneck Wall Mount HelixTM HelixTM Wall Mount SPOUT Drain Drain Pipe Flexible Tube except for Integrated Mounting Bracket Nozzle Strainer Tool 1 16...

Страница 3: ...erve all local and plumbing codes Check the cold and hot water supply pressure Make sure the cold water supply pressure is higher or equal to the hot water supply pressure When the water supply pressu...

Страница 4: ...controller in place and tighten the nuts on the inlet brackets to secure it IN COLD IN OUT HOT IN OUT Ill 3 Wall Anchors not included Wall Anchors not included Water Inlet Bracket Self Tapping Screw...

Страница 5: ...ing bracket through a hole in the wall with the set screw hole located at 12 o clock Mark the loca tion of the set screw hole on the wall and remove the mounting bracket For sheet metal surface Drill...

Страница 6: ...ill ash Do not place your hands or other objects in front of the sensor while the sensor light is ashing as it will interfere with the range adjustment process If the sensor light continues to ash for...

Страница 7: ...he temperature opposite of the direction indicated make sure the hot water supply is connected to the left inlet bracket Open Close Stop Valve Ill 1 Ill 2 CARE CLEANING Drain Ryohan only To remove the...

Страница 8: ...e mounting bracket and mounting nuts behind the sink wall refer to Install the Spout section are tight Adjust the Temperature For thermostatic mixing models turn the temperature control handle a few t...

Страница 9: ...ure control handle is set at C Set the temperature control handle to the middle point The stop valve connected to the hot water supply is not fully opened Open the hot water stop valve fully The hot w...

Страница 10: ...bleach alkali acid cleaners dry powder cleaners or any other abrasive cleaners or the use of metal or nylon scrubbers 4 In order for this limited warranty to be valid proof of purchase is required TO...

Страница 11: ...to por lo Integrado Soporte para Montaje Herramienta Boquilla Filtro 1 16 2mm Llave Allen Arandelas Lat n x1 Hule x1 Tuerca de Lat n x2 Tornillo Phillips x3 4mm x 40 Taquete de Tornillo x3 Tornillo 3m...

Страница 12: ...inistro de agua es mayor a 125 psi 826 kPa aseg rese de reducir la presi n dentro de un intervalo de 20 a 80 psi utilizando una v lvula reductora de presi n se vende por separado El intervalo ptimo pa...

Страница 13: ...olador en su lugar y apriete las tuercas en los soportes de la entrada para asegurarlo Para instalar los modelos con cubierta montada NOTA Se recomienda ampliamente dejar un ori cio para el grifo de 1...

Страница 14: ...las 12 en punto Marque la ubicaci n del ori cio del tornillo de jaci n en la pared y retire el soporte de montaje Para una super cie de hoja de metal Perfore un ori cio de 3 16 4 8 mm en la ubicaci n...

Страница 15: ...jetos enfrente del sensor mientras la luz del sensor est parpadeando ya que puede interferir con el proceso de ajuste del rango Si la luz del sensor sigue parpadeando por m s de 20 segundos se deber r...

Страница 16: ...tura se cambia la temperatura a la direcci n opuesta de la indicada aseg rese que el suministro de agua caliente est conectado al soporte de entrada izquierdo Abrir Cerrar V lvula de Cierre Ill 1 Ill...

Страница 17: ...ntaje y las tuercas de jaci n detr s del lavabo pared con sulte la secci n Instale el surtidor est n apretadas Ajuste la Temperatura Para los modelos de mezclado t rmico gire la manija del control de...

Страница 18: ...do baja La manija del control de temperatura est ja en C Fije la manija del control de temperatura en el punto medio La v lvula de suspensi n conectada al suministro de agua cali ente no est completam...

Страница 19: ...limpiadores secos talco u otros limpiadores abrasivos o el uso de estropajos de metal o nylon 4 Con el n de que esta garant a limitada sea v lida se requiere una prueba de compra TOTO le aconseja el r...

Страница 20: ...tion Tuyau d vacuation Tube Flexible sauf pour l Int gr Support de Montage Embout Outil de Cr pine 1 16 2mm Cl Allen Rondelles Laiton x1 Caoutchouc x1 crou en Laiton x2 Vis Phillips x3 4mm x 40 Ancrag...

Страница 21: ...d eau froide soit plus lev e que celle de la source d eau chaude Lorsque la pression de la source d eau est plus lev e que 125psi 826kPa soyez sure de r duire la pression dans une fourchette de 20 80...

Страница 22: ...rrez les crous sur les supports d entr e eau pour le garder en place Ancrages Mural pas inclus Ancrages Mural pas inclus Support d Entr e d Eau Vis Auto Taraudeuse Vis Auto Taraudeuse Support d Entr e...

Страница 23: ...vis de r glage situ e la position 12 heures Marquez l emplacement du trou de la vis de r glage sur le mur et enlevez le support de montage Pour la t le Percez un trou 3 16 4 8 mm l endroit marqu NOTE...

Страница 24: ...ou d autres objets devant le capteur pendant que sa lumi re clignote parce que ceci va interf rer avec le processus d ajustement du champ de d tection Si la lumi re du capteur continue clignoter pend...

Страница 25: ...ection indiqu e assurez vous que la source d eau chaude soit connec t e la gauche du support d entr e Ouvrir Fermer Valves d Arr t Ill 1 Ill 2 Drain Ryohan seulement Pour enlever l unit de la coupe de...

Страница 26: ...r Voir la section Installer le bec sont bien serr s Ajustez la Temp rature Pour les mod les de m lange thermostatique tournez la poign e de contr le de la temp rature un certain nombre de fois par an...

Страница 27: ...asse La poign e de contr le de la temp rature est x e C Fixez la poign e de contr le de la temp rature au point du milieu La valve d arr t connect e la source d eau chaude n est pas compl tement ouver...

Страница 28: ...les conditions atmosph riques inclus et non limit s l utilisation de l eau de blanchissant alcanes nettoyants acides nettoyants sec poudre ou tout autre nettoy ants abrasifs ou l utilisation de m tal...

Страница 29: ...NTROLLER CONTROLADOR DE MEZCLADO T RMICO CONTR LEUR DE M LANGE THERMIQUE DECK MOUNTED SPOUTS SURTIDORES MONTADOS EN MOSTRADOR BEC MONT S SUR PONT 4 1 2 114mm 2 50mm FRONT VIEW VISTA FRONTAL VUE AVANT...

Страница 30: ...cio del grifo 1 1 8 29mm La adici n del recubrimiento detr s de la pared se recomienda para la instalaci n en pared laminada NOTE paisseur maximum du mur 2 Acc s requis de l arri re Diam tre du trou d...

Страница 31: ...idor Ensemble de Montage du Bec 5 Spout Nut Tuerca del Surtidor crou Pour le Bec 6 Flexible Tube Tubo Flexible Tube Flexible Helix Fordham 4 5 6 3 2 1 No Description Descripc on Description 1 Spout As...

Страница 32: ...Tube Flexible Ryohan No Description Descripc on Description 1 Spout Assembly Montaje del Surtidor Assemblage du Bec 2 Sensor Set Set del Sensor Ensemble du Capteur 3 Nozzle Assembly Set Set del Monta...

Страница 33: ...egulator Regulador R gulateur 10 Back up Battery Bater a de Respaldo Batterie de Secours Single Supply Dynamo D namo del Suministro Individual Dynamo d Approvisionnement Unique No Description Descripc...

Страница 34: ...uiry For product warranty registration TOTO U S A Inc recommends online warranty registration Please visit our web site http www totousa com If you have questions regarding warranty policy or coverage...

Отзывы: