Testing and Adjustment
Turn on the water supply.
Turn on the water supply at the stop valves and inspect all the
connections for any leaks (see Ill. 1).
Flow Rate Adjustment.
IMPORTANT
: The EcoPower Automatic Faucets must be used
with the stop valves fully opened whenever possible. Insuffi -
cient fl ow rate will result in power shortage and consumption of
the built-in backup battery.
If fl owrate adjustment is necessary because the wash basin
is too small or the water pressure is too high, turn the stop
valve(s) clockwise to limit the fl ow. Confi rmation of wash basin
specifi cations is highly recommended before installation of the
Automatic Faucet
.
Temperature Adjustment (thermal mixing models only)
.
The water temperature has been factory set at 100°F (38°C,
Max: 42°C ± 3°C). Depending on the supply water pressure and
other local conditions, the water temperature may not be kept
as specifi ed. In such a case, adjust the temperature by turning
the temperature control handle (see Ill. 2).
NOTE: If turning the temperature control handle changes the
temperature opposite of the direction indicated, make sure the
hot water supply is connected to the left inlet bracket.
Open
Close
Stop Valve
Ill. 1
Ill. 2
CARE & CLEANING
Drain (Ryohan only)
To remove the drain cup for cleaning (see Ill. 2):
1. Pull the drain cup unit fi rmly to the drain part, then release it.
2. Turn the drain cup unit clockwise 45 degrees.
3. Pull the drain cup upwards and out.
NO TE: If the drain cup unit does not come out, put it back and
while turning it clockwise once again, slowly pull it out.
Spout and Sensor
IMPORTANT! Do not scratch the sensor when cleaning the
spout (see Ill. 1).
Avoid using any cleaning materials that may scratch the spout
surface.
Never use polishing powder, detergent that includeds coarse
particles, thinners, benzene, acids, alkaline detergents, or nylon
scrub brushes, as they can damage the surface of the spout.
To safely clean the surface, wipe it using a dampened soft cloth
with diluted dishwashing detergent and dry it with another soft
cloth. If this does not adequately clean the surface, wipe the
area with a neutral detergent and wet cloth.
Hot
Cold
Temperature
Control
Handle
Ill. 1
Sensor
Area
Outlet
Drain
Cup
Unit
Main
Drain
Body
Ill. 2
Hot
Cold
Temperature
Control
Handle
Sensor
area
Outlet