4
ENGLISH
3) Measure the distance X from the
front of the valve to the finished wall
surface. Compare that measurement
to the following table to determine
which valve stem is needed.
Install the proper valve stem.
IM PORTANT:
Before proceeding
turn the valve stem extension
counterclockwise until it stops.
4) Using the four screws removed in Step
2, secure the volume control assembly
to the valve in the correct orientation
as described below:
Aimes 1-way Trim (TS626C2):
Secure with the short end of the
handle at 12 o’clock and the two
notches at 6 o’clock.
Aimes 2-way Trim (TS626D2):
Secure with the short end of the
handle at 9 o’clock and the two
notches at 6 o’clock.
Legato 1-way and 2-way Trims
(TS624C2/D2):
Secure with the two notches at 6
o’clock.
5) Align the tab on the top of the back of the face-
plate with the top notch on the volume control
assembly, and turn the faceplate clockwise until it
locks in place.
Secure the faceplate with the included set screw.
F or Aimes (TS626C2/D2), please slide over the
faceplate through handle carefully.
Installation Procedure (continued)
X
Finished Wall
Surface
FOR AIMES MODELS:
TS626C2
(1 Way)
TS626D2
(2 Way)
X
Install
Less than 1” (25mm)
Short Stem
More than 1” (25mm)
Long Stem *
Legato Volume
Control Assembly
* Pre-installed on the valve