Repairs to the patio heater may only be carried out by a qualified technician
PROBLEM
SOLUTION
Gas valve may be OFF
Turn the
gas valve ON
LPG cylinder empty
Refill
LPG cylinder
Orifice blocked
Clean or replace Orifice
Air in supply system
Purge air from lines
Pilot will not light
Loose connection
Check all fittings
Debris around pilot
Clean dirty area
Loose connection
Tighten connection
.
Thermocouple bad
Replace Thermocouple
Gas leak in line
Check connections
Pilot will not stay on
Lack of gas pressure
LPG cylinder is near empty
Gas pressure is low
LPG cylinder is near empty
Orifice blocked
Remove, clean and replace
Control knob not ON
Turn knob to ON
.
Thermocouple bad
Replace Thermocouple
Burner will not light
Pilot light assembly bent
or not in correct location
.
Place pilot light in correct positi on
and retry
PROBABLE CAUSE
- 12 -
Distributed by: D.K.Gas Appliances. PO Box 34191 Erasmia 0023
website:
email: [email protected]
www.totai.co.za
Issue 1-2018
TAMPERING:
Under no circumstances are you allowed to tamper with the jet sizes or modify anything on
the appliance. Not only is it dangerous , it will also nullify your warranty
NOTE:
GAS-PRESSURE REGULATOR—This appliance is designed to operate on a gas pressure of
2,8 kPa. A suitable regulator that complies with the requirements of SANS 1237 must be used
with this appliance
TECHNICAL SPECIFICATIONS
Name
Specification
Model number
16/DK1027
Heat Output
11,0 kw
Gas Type
LPG
Jet sizes
Main burner 1,51 mm Pilot burner 0,22 mm
Operating Pressure
2,8 kPa
Gas consumtion (max.)
750 g/h