OPERATION AND STORAGE

TO TURN ON THE HEATER

1. Turn on the valve on the gas supply cylinder completely.
2. Press and turn the variable control knob to PILOT position (counter-clockwise 90º).
3. Press down the variable control knob and hold for 30 seconds. While holding down the variable control
knob, press the igniter button several times until the pilot flame lights. Release the variable control knob after
the pilot flame lights.
Note:

If a new tank has just been connected, please allow at least one minute for the air in the gas pipeline to

purge out through the pilot hole.

When lighting the pilot flame make sure that the variable control knob is continuously pressed down

while pressing the igniter button. Variable control knob can be released after the pilot flame lights.

Pilot flame can be watched and checked from the small round window with sliding lid located at the

bottom of the flame screen (to the left or right side of the controller).

If the pilot flame does not light or it goes out, repeat step 3.

4. After the pilot flame lights, turn the variable control knob to maximum position and leave it there for 5
minutes or more before turning the knob to desired temperature position.

TO TURN OFF THE HEATER

1.Turn the variable control knob to PILOT position.
2.Press and turn the variable control knob to OFF position.

3.Turn off the valve on the gas supply cylinder completely.

Storage

1. Always close the gas valve of the gas cylinder after use or in case of a disturbance.
2. Remove the pressure controller and the hose.
3. Check the tighness of the gas valve and for damage. If you suspect damage, have it changed by your gas
dealer.
4. Never store liquid gas cylinder in a sub-terrain, or at places without adequate air ventilation.

-4-

Variable control knob

Igniter

lgniter

Содержание 16/DK1021A

Страница 1: ...the vicinity of this or other any other appliance Any LPG cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING HAZARDOUS FIRE OR EXPLOSION MAY RESU...

Страница 2: ...ol panel or top canopy re ector Control compartment burner and circulation air passageways must be kept clean Frequent cleaning may be necessary as required The LPG Cylinder should be turned off when...

Страница 3: ...re petrol or other ammable liquids or vapours are stored To protect heater from strong wind anchor the base securely to the ground with screws HEATER STAND AND LOCATION GAS REQUIREMENTS LEAKAGE TEST G...

Страница 4: ...can be watched and checked from the small round window with sliding lid located at the bottom of the flame screen to the left or right side of the controller If the pilot flame does not light or it go...

Страница 5: ...burner to keep it clean and safe for use Cover the burner unit with the optional protective cover when the heater is not in use PARTS AND SPECIFICATIONS 5 2222 mm 2003 mm 765 mm 813 mm 460 mm Re ecto...

Страница 6: ...oap solution for leakage test Parts supplied Assembly post with 3 pcs post brackets Reflector 813 mm with 9 pcs 8 mm washers 3 pcs M8 castle nut and 3 pcs M8 burner reflector support bolt 4 pcs bolts...

Страница 7: ...n the picture 1 2 Use 3 pcs M8 x 16 mm bolts to join the post brackets and stand STEP 2 2 1 Put the post on the top of 3 pcs post brackets 2 2 Use 6 pcs M6 x 35 mm bolts and nuts to connect the post t...

Страница 8: ...1 5 1 Check whether the connection of vertical post and burner are assembled according to instructions and all bolts and nuts are tightened 5 2 Put washer 8 mm on each reflector support bolt 6 2 Faste...

Страница 9: ...on the post plate Connect the regulator to the gas cylinder and tighten it with adjustable wrench Put LPG cylinder on the stand Connect the end thread of inlet gas hose to the regulator STEP 7 7 1 7...

Страница 10: ...linder is near empty Gas pressure is low LPG cylinder is near empty Ori ce blocked Remove clean and replace Control knob not ON Turn knob to ON Thermocouple bad Replace Thermocouple Burner will not li...

Отзывы: