Use a 9 kg LPG cylinder only
Ÿ
The hose must comply with the requirements of SANS 1156-2 or BS 2312
Ÿ
A dented, rusted or damaged LPG cylinder may be hazardous and should not be used
Ÿ
Never use a cylinder with a damaged valve connection
Ÿ
The cylinder valve must have a horizontal outlet with a G5/8 left hand thread to suit the regulator
Ÿ
Never connect the cylinder directly to the heater . A regulator must always be used
Ÿ
The regulator must comply with the requirements of SANS 1237.
Ÿ
The heater is for outdoor use only. Always ensure that adequate fresh air
ventilation is provided.
Ÿ
Always maintain proper clearance to combustible materials, i.e. top 100 cm
and sides 100 cm minimum.
Ÿ
Heater must be placed on level firm ground.
Ÿ
Never operate heater in an explosive atmosphere like in areas where petrol or
other flammable liquids or vapours are stored.
Ÿ
To protect heater from strong wind, anchor the base securely to the ground
with screws.
HEATER STAND AND LOCATION
GAS REQUIREMENTS
LEAKAGE TEST
Ÿ
Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas tightness
check must be performed at the installation site due to possible mishandling in shipment or excessive
pressure being applied to the heater.
Ÿ
Make a soap solution of one part liquid detergent and one part water. The soap solution can be applied with a
spray bottle, brush or rag. Soap bubbles will appear in case of a leak.
Ÿ
The heater must be checked with a full cylinder.
Ÿ
Make sure the safety control valve is in the OFF position.
Ÿ
Turn the gas supply ON.
Ÿ
In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply on and re-
check.
Ÿ
Never leak test while smoking.