Name
TOTAI
Model
Heat Output
13.0 KW
Gas Types
LPG
Injector Size
Ø 1.90mm x 1
Operating
Pressure
2.8 kPa
Gas Consumption (at Max )
940 g/h
PROBLEM
PROBABLE CAUSE
SOLUTION
Gas valve may be OFF
Turn the
gas valve ON
LPG cylinder empty
Refill
LPG cylinder
Orifice blocked
Clean or replace Orifice
Air in supply system
Purge air from lines
Pilot will not light
Loose connection
Check all fittings
Debris around pilot
Clean dirty area
Loose connection
Tighten connection
.
Thermocouple bad
Replace Thermocouple
Gas leak in line
Check connections
Pilot will not stay on
Lack of gas pressure
LPG cylinder is near empty
Gas pressure is low
LPG cylinder is near empty
Orifice blocked
Remove, clean and replace
Control knob not ON
Turn knob to ON
.
Thermocouple bad
Replace Thermocouple
Burner will not light
Pilot light assembly bent
or not in correct location
.
Place pilot light in correct positi on
and retry
Repairs to the patio heater may only be carried out by a qualified technician
TAMPERING:
Under no circumstances are you allowed to tamper with the jet sizes or modify anything on
the appliance. Not only is it dangerous , it will also nullify your warranty
NOTE:
GAS-PRESSURE REGULATOR—This appliance is designed to operate on a gas pressure
of 2,8 kPa. A suitable bullnose regulator that complies with the requirements of SANS 1237
must be used with this appliance
Technical Specifications
Troubleshooting
FOR OUTDOOR USE ONLY
Specifications are subject to change without prior notice
16/DK1021A & 16/DK1022A