Startup and operation
RES-409
Page 19
9.2.2
Configuration of the rotary coding
switch for the temperature range
and alloy (as of January 2007)
This configuration is provided as standard
on all controllers manufactured as of
February 2007. On older controllers, the
configuration must be set via the CAN interface
(
section 10.3 "Receiving CAN messages" on
page 27).
All controllers manufactured as of February
2007:
The settings with the rotary coding switch are
considered to be the factory setting. This
corresponds to CAN message address 8, value 10
(dec) (
section 10.3 "Receiving CAN messages"
If the switch is set to "9" (as of February 2007), other
temperature ranges and alloys can be selected in the
ROPEX visualization software (
"Diagnostic interface / visualization software (as of Feb-
ruary 2007)" on page 43). CAN message address 8
must contain the value 10 (dec) for this purpose (
see
section 10.3 "Receiving CAN messages" on page 27).
9.2.3
Configuration of the fault relay
If the jumper is not inserted, the fault relay is
permanently energized (fault contact
between terminals 13 and 14 closed). The other
controller functions (e.g. heatsealing band heating,
AUTOCAL etc.) are not affected.
If the "Fault output deenergized at fault/PC CONFIGU-
RATION" position is selected (as of February 2007),
the behavior of the fault output can be configured more
finely in the ROPEX visualization software (
see
section 10.12 "Diagnostic interface / visualization soft-
ware (as of February 2007)" on page 43).
0
5
1
2
3
4
6
7
8
9
0
5
1
2
3
4
6
7
8
9
Switch
position
0
1
4
5
8
300°C
300°C
500°C
500°C
300°C
1100ppm/K
780ppm/K
1100ppm/K
780ppm/K
3500ppm/K
e.g. Alloy-20
e.g. Alloy L
e.g. Alloy-20
e.g. Alloy L
e.g. NOREX
Temp.
range
Temp.
coefficient
Band
alloy
0 = Factory settings
SWITCH POS.
1
0
4
5
8
9
TEMP. RANGE
300°C
300°C
500°C
500°C
300°C
PC CONFIGURATION
ALLOY
780ppm/K
1100ppm/K
(L)
(A20)
1100ppm/K
(A20)
780ppm/K
3500ppm/K
(L)
(NOREX)
9
PC-CONFIGURATION
!
!
0
5
1
2
3
4
6
7
8
9
Alarm relay de-
energized by alarm/
PC-CONFIGURATION.
Alarm relay energized
by alarm.
(factory setting)
CONFIGURATION
ALARM OUTPUT
DE-ENERGIZED / PC
AT ALARM
ENERGIZED
!