Technical data
Page 8
RES-409
6
Technical data
Type of construction
Housing for installation in the electrical cabinet
Snaps onto a standard top hat rail (DIN TS35 rail, 35 mm) acc. to DIN EN 50022
Dimensions: 90 x 75mm; height: 135mm (incl. terminals)
Line voltage
All controllers manufactured as of February 2007:
115VAC version: 110VAC -15%…10% (equivalent to 94…132VAC)
230VAC version: 220VAC -15%…10% (equivalent to 187…264VAC)
400VAC version: 380VAC -15%…10% (equivalent to 323…456VAC)
All controllers manufactured as of January 2004 up to January 2007:
115VAC version: 115VAC -15%…10% (equivalent to 98…132VAC)
230VAC version: 230VAC -15%…10% (equivalent to 196…264VAC)
400VAC version: 400VAC -15%…10% (equivalent to 340…456VAC)
All controllers manufactured up to December 2003:
115VAC, 230VAC or 400VAC, tolerance: +10% / -15%
depending on version selected (
section 13 "How to order" on page 53)
Line frequency
47…63Hz, automatic adjustment to frequencies in this range
CAN-Bus interface
CAN Bus-interface type CAN 2.0A according ISO 11898
(CANopen is not supported)
2 x 3-pole M8 circular connector acc. to IEC 947-5-2
All controllers manufactured as of February 2007:
Baud rates:
20kBaud; 50kBaud; 100kBaud, 125kBaud; 205kBaud;
250kBaud; 500kBaud; 800kBaud; 1MBaud
All controllers manufactured up to January 2007:
Baud rates:
10kBaud; 50kBaud; 125kBaud; 205kBaud;
250kBaud; 500kBaud; 800kBaud; 1MBaud