– 79 –
INTERFACE MANUAL
STE 85457
Designation
AUTORUN (Auto mode ON)
Output terminal
OUTPUT-8 pin
Signal logic
Signal judgment
Output terminal
ON
OFF
High
Low
Function
This signal turns on when the robot is operating in the
automatic operation mode.
When the RUN signal is made valid after the SYS_RDY signal
is turned on, automatic operation starts with this signal output.
This signal remains on as long as the robot is operating in the
automatic operation mode.
This signal turns on when the EXT. SIGNAL or EXT. HOST
mod is selected by means of the MODE switch of the
TSL3000E/TSL3100E robot controller.
Signal timing
SYS_RDY (O)
RUN (I)
STOP (I)
AUTORUN (O)
Cautions
This signal will not turn on while the TEACH mode is selected
by means of the MODE switch of the TSL3000E/TSL3100E
robot controller.
Содержание TSL3000E