– 102 –
INTERFACE MANUAL
STE 85457
*
To designate the slave station number of the TSL3000E/TSL3100E, observe
the following steps. Under [U12] of the USER.PAR (user parameter) file, you
can find the following parameter setting related to the extension input and
output.
[U12] Extend I/O setting
{Use/Not Use} (0: Not Use, 1: Use)
{Not Use}
{Not Use}
= 0 28 20
Corresponds to station 0.
= 0 28 20
Corresponds to station 1.
If you wish to use only station 0 (i.e., one (1) TR48DIOC module), for instance,
change the underlined bit corresponding to station 0 to "1".
= 1 28 20
= 0 28 20
After saving the parameter file, turn off the controller power and on again.
Then the above parameter becomes effective.
If you wish to use both stations 0 and 1 (i.e., two (2) TR48DIOC modules),
specify as follows and perform the same operation as above to make the
parameter valid.
= 1 28 20
= 1 28 20
When using the TR48DIOC module, careful precautions should be taken on the
following matters.