– 104 –
INTERFACE MANUAL
STE 85457
7.3
Attaching and Detaching External I/O Cable
For the external I/O cable, use the cable attached to the TR48DIOCN/TR48DIOC
module, or a cable which meets the specifications.
Before attaching or detaching the external I/O cable to or from the
TSL3000E/TSL3100E robot controller, be sure to turn off the main power.
Twisted wire:
0.3 mm
2
- 0.75 mm
2
(Unpeeled wire length: 9 mm)
Slotted-head
screwdriver
Cable insertion
release button
Move in direction of
arrow to unlock
Locked
Connector:
ML-4000-CP-5PGY
Fig. 7.4 Attaching and detaching external I/O cable
To connect the external I/O cable, press a slotted-head screwdriver onto the cable
insertion release button of the connector as shown in Fig. 7.4 to lock the cable
insertion release button so that the cable can be inserted or removed. After the
cable is firmly pressed in, raise the cable insertion release button upwards to
release the lock.
(Lightly pull the cable and make sure that the cable is connected completely and will
not come off. DO NOT pull the cable by force, however. Otherwise, an unusually
large force is exerted on the cable, resulting in loose cable connection.)
To remove the cable, press the slotted-head screwdriver onto the cable insertion
release button so that the cable insertion release button is locked, and then pull out
the cable.