background image

IIII

TLPB2 Service Manual    Rev. 2.0

   

     

 

The lightning flash with arrowhead
symbol, within an equilateral triangle,
is intended to alert the user to the
presence of uninsulated "dangerous
voltage" within the product's
enclosure that may be of sufficient
magnitude to constitute a risk of
electric shock to persons.

The exclamation point within an
equilateral triangle is intended to
alert the user to the presence of
important operating and
maintenance (servicing) instructions
in the literature accompanying the
appliance.

WARNING:    TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS

APPLIANCE TO RAIN OR MOISTURE. DANGEROUS HIGH VOLTAGES ARE
PRESENT INSIDETHE ENCLOSURE. DO NOT OPEN THE CABINET. REFER
SERVICING TO QUALIRED PERSONNEL ONLY.

CAUTION:

      Laser beam is emitted when the laser button of the remote control is pressed. Do not

look from the front of the remote control. Do not face toward a person or to a mirror.

FCC Radio Frequency Interference Statement

Note:

              This equipment has been tested and found to comply with the limits for a Class A

digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiates radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his
own expense.

WARNING:

    Changes or modifications made to this equipment, not expressly approved by

Toshiba, or parties authorized by Toshiba, could void the user's authority to operate
the equipment.

Notice:

            This Class A digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe A est conforme à la norme NMB-003 du
Canada.

IMPORTANT PRECAUTIONS

Save Original Packing Materials

The original shipping carton and packing materials will come in
handy if you ever have to ship your LCD projector. For maximum
protection, repack the set as it was originally packed at the factory.

Avoid Volatile Liquid

Do not use volatile liquids, such as an insect spray, near the unit.
Do not leave rubber or plastic products touching the unit for a long
time. They will mar the finish.

Moisture Condensation

Never operate this unit immediately after moving it from a cold
location to a warm location. When the unit is exposed to such a
change in temperature, moisture may condense on the crucial
internal parts. To prevent the unit from possible damage, do not use
the unit for at least 2 hours when there is an extreme or sudden
change in temperature.

In the spaces provided below, record the Model and Serial No.    Iocated
at the rear of your LCD projector.

Mode No.                                                Serial No.                                                

Retain this information for future reference.

SAFETY PRECAUTIONS

Содержание TLP-S10

Страница 1: ...SERVICE MANUAL FILE NO 330 200310 SAFETY PRECAUTION 3LCD PROJECTOR TLP T70M TLP T71M TLP T60M TLP T61M Document Created in Japan Aug 2003 U TLP S40 TLP S41 TLP S10 ...

Страница 2: ... time Measure the AC voltage across the combina tion of 1500ohm resistor and 0 15 µF capacitor Reverse the AC plug at the AC outlet and repeat AC voltage mea surements for each exposed metallic part Voltage mea sured must not exceed 5 25V rms This corresponds to 3 5 mA AC Any value exceeding this limit consti tutes a potential shock hazard and must be corrected immediately PRODUCT SAFETY NOTICE Ma...

Страница 3: ...e instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications made to this equipment not expressly approved by Toshiba or parties authorized by Toshiba could void the user s au...

Страница 4: ... and to ensure reliable operation of the product and to protect it from overheating and these openings must not be blocked or covered The openings should never be blocked by placing the product on a bed sofa rug or other similar surface This product should not be placed in a built in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer s instructions ha...

Страница 5: ...ion to overturn IMPORTANT SAFETY INSTRUCTIONS 16 Damage Requiring Service Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions a When the power supply cord or plug is damaged b If liquid has been spilled or objects have fallen into the product c If the product has been exposed to rain or water d If the product does not operate n...

Страница 6: ...SERVICE MANUAL FILE NO 330 200310 ELECTRICAL ADJUSTMENT 3LCD PROJECTOR TLP T70M TLP T71M TLP T60M TLP T61M Document Created in Japan Aug 2003 U TLP S40 TLP S41 TLP S10 ...

Страница 7: ... image Fig 5 2 appears Fig 5 2 Adjustment software DPJAdjustmentTool2 exe operates following adjustments a Initial setting of keystone correction KEYSTONE b Initial adjustment of input signal level SUB c LCD panel drive center voltage adjustment VCOM d LCD panel gamma adjustment GAMMA e LCD panel color shading adjustment SHADING Note When replacing main PC board adjustment procedure of item a to e...

Страница 8: ... as a base Moreover the micro computer memorizes the level position data when the sensor is warmed up with the heat run The data is used to correct the temperature drift correction 2 1 Adjustment of low temperature 1 Select KEYSTONE from starting menu Check 0 30 30 and click Start button 2 Set the projector on a level surface Click OK to start 3 Keep projector on 30 degree and click OK 4 Keep proj...

Страница 9: ...or on a level surface and make sure it is warm enough Click OK button 3 Click OK button 4 After the adjustment click Close to exit Note Only for the keystone correction initialization of high and low temperatures at one time check both 0 30 30 and 0 High temperature check boxes on the menu and click start In this case perform enough heat run before starting the initializing of 0 High temperature ...

Страница 10: ... input Screen resolution selection is executed on the Display Properties 4 Input all white signal to the XGA and click OK button 3 Input signal level adjustment Perform the adjustment when main PC board is replaced This procedure corrects variation of input signal level by each main PC board and adjusts to stabilize The input signal level is adjusted automatically with specified signal inputting 1...

Страница 11: ...e Covering the lens of the camera with hand makes Black 100 signal 8 When the following message appears click yes 9 When the following message appears touch the camera lens on a bright light The screen should be all white The click OK button Note Touching the camera lens on a bright light makes White 100 signal So the screen will be all white 10 After the adjustment was completed the following mes...

Страница 12: ...o the LCD panel center voltage of specified range is adjusted to output symmetrical wave If this voltage is out of alignment the LCD panel is damaged by flicker or burning So it must adjust completely R G and B panels should be adjusted for each front projection mode Front and Ceiling hunger projection mode Ceiling 1 Start signal generate software SINGO98 exe and select the Burst signal to output ...

Страница 13: ...and lowest data 5 Select Ceiling button Adjust in the same procedures as step 4 and click the Save to save the data 5 Gamma Adjustment Perform the adjustment when main PC board is replaced The VT input voltage optical transmissivity characteristics of the LCD panel are uneven So gamma correction is required The adjustment is used to write already corrected gamma data after the main PC board replac...

Страница 14: ...e status 4 After the transfer is completed the following message appears Click OK button 3 Click OK to complete 4 Replace the main PC board with new one and turn on power of the projector 5 Select GAMMA from the staring menu and click Send 6 Select the previously saved file step 2 and click Open 7 After the transfer is completed the following message appears Click OK button Note The transferred ga...

Страница 15: ...from Projector menu During loading the data Please Wait message appears in the box 2 After the shading data loading is complete the following message appears Click OK button 3 Save the downloaded shading data to the PC Select Save from File menu 4 Input file name serial number etc and click Save button 5 Replace the main PC board with new one and turn on the power of the projector 6 Select Load fr...

Страница 16: ...d file step 4 and click Open Click Open button 9 Select Send from Projector menu to load the saved data in the main PC board 10 When the following message appears click YES button 11 After the transfer data is complete click OK button 12 Save the data Click Save Data to save the data from Projector menu ...

Страница 17: ...the adjustment software 2 Select a color Red Green Blue for adjustment from the Setting menu 3 Select a level Max Mid1 Mid2 Min form the Setting menu 4 Select Built in Signal from Check menu 5 Input the luminous signal level on White box and click OK button And then click Close Note Set the luminous signal level of each internal level as follows common to the colors MAX 75 MID1 50 MID2 26 MIN 11 E...

Страница 18: ...SERVICE MANUAL FILE NO 330 200310 LED DISPLAY SERVICE MODE 3LCD PROJECTOR TLP T70M TLP T71M TLP T60M TLP T61M Document Created in Japan Aug 2003 U TLP S40 TLP S41 TLP S10 ...

Страница 19: ...rature error Camera error The power turns off caused by camera error Transmission problem of the camera unit Device error The power turns off or does not come on There are problems with the sensor PC board or the main PC board Solution Check the power unit Check the connector Check the main PC board Make the lamp cool Even if it does not work Change a new lamp Or it may have a trouble at the balla...

Страница 20: ... screen When you press MENU button it will disappear C10 TLP T71M 1000 1000 L 10 30 50 P 10 30 50 T 10 30 50 Sub B 109 114 124 Sub C 100 110 99 KC0 T 39 P 10261 H 5055 KC1 T 40 P 10264 H 5944 KC2 T 41 P 10263 H 4160 KC3 T 44 P 10306 H 5084 Err 9 Shutdown 7 List 13 1 1 2 1 1 13 13 10 0 the latest error the older error Past ten times Transmission speed Firmware version of the camera unit the model w...

Страница 21: ...SERVICE MANUAL FILE NO 330 200310 PARTS LIST 3LCD PROJECTOR TLP T70M TLP T71M TLP T60M TLP T61M Document Created in Japan Aug 2003 U TLP S40 TLP S41 TLP S10 ...

Страница 22: ... of replacement is to be identical with originals The substitute replacement parts which do not have the same safety characteristics as specified in the parts list may cause shock fire or other hazards NOTICE The part number must be used when ordering parts in order to assist in processing be sure to include the model number and description EXPLODED VIEWS Packing Assembly ...

Страница 23: ... Audio Cable for Computer Audio Cable Camera Extension Cable CDŹROM Owner s Manual Mouse Remote Control Set Battery AV Cable Quick Sheet INPU T R CLIC K PLA Y STO P PJ M O DE LASE R V O L M E N U E N TE R Y210 Y101 Y102 Y103 Y050 Y265 Y240 Y241 Y221 Y229 Y231 Y232 Y200 Y201 Y203 Y256 Y260 Accessories Y100 ...

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ...49 23372149 23372149 23372149 23372149 23372149 E200 OPTICAL ENGINE 23405297 23405297 23405298 23405298 23405299 23405299 23405300 LENS 23405302 23405302 23405303 23405303 23405303 23405303 23405304 OPTICAL PARTS MAIN FRAME 23405306 23405306 23405307 23405307 23405308 23405308 23405309 OPTICAL PARTS SUB FRAME 23405311 23405311 23405311 23405311 23405311 23405311 23405312 POLARIZAR I R 528 23405314...

Страница 32: ...75000616 75000650 A280 LENS CAP 23890052 23890052 23890052 23890052 23890052 23890052 23890052 A403A PACKING R 23946632 23946632 23946632 23946632 23946632 23946632 23946719 A403B PACKING L 23946633 23946633 23946633 23946633 23946633 23946633 23946720 A403C PACKING 23946721 P HOLDER SERVICE KIT T70 T60 23587099 23587099 23587099 23587099 P HOLDER SERVICE KIT T40 23587138 23587138 P HOLDER SERVICE...

Страница 33: ...1 1 SHIBAURA 1 CHOME MINATO KU TOKYO 105 8001 JAPAN ...

Отзывы: