Troubleshooting Procedures
Satellite C800 and Satellite L800
Maintenance Manual (960-Q08)
41
Procedure 2
Replacement Check
If External microphone/Headphone does not work properly, perform check 1.
If internal microphone /Speaker do not work properly, perform check 2.
If HP out does not work properly, perform check 3.
If Volume control does not work properly, perform check 4.
Check 1
External microphone/Headphone may be faulty. Replace it with a new one
following the steps in Chapter 4. If the problem still occurs, perform Check 5.
Check 2
Internal microphone /Speaker may be faulty. Replace it with a new one following
the steps in Chapter 4. If the problem still occurs, perform Check 5.
Check 3
HP out may be faulty. Replace it with a new one following the steps in Chapter 4.
If the problem still occurs, perform Check 5.
Check 4
Volume control may be faulty. Replace it with a new one following the steps in
Chapter 4. If the problem still occurs, perform Check 6.
Check 5
Flat cable between AD board/Speaker and system board may be faulty. Replace it
with new cable following the instructions in Chapter 4. If the problem still occurs,
perform Check 6.
Check 6
Audio board/System board may be faulty. Replace it with a new one following the
instructions in Chapter 4.
Содержание Satellite L800
Страница 12: ...Satellite C800 and Satellite L800 Maintenance Manual 960 Q08 Chapter 1 Hardware Overview ...
Страница 15: ...Chapter 1 Hardware Overview Satellite C800 and Satellite L800 Maintenance Manual 960 Q08 iv ...
Страница 45: ...2 1 Satellite C800 and Satellite L800 Maintenance Manual 960 Q08 Chapter 2 Troubleshooting Procedures ...
Страница 90: ...Test Program for Field Satellite L840 Tests and Diagnostics Manual 1 Chapter 3 Diagnostic Programs ...
Страница 92: ...Test Program for Field Satellite L840 Tests and Diagnostics Manual 1 Chapter 3 Diagnostic Programs ...
Страница 189: ...Replacement Procedures Satellite C800 and Satellite L800 Maintenance Manual 960 Q08 33 ...