Wireless remote controller
(RBC-AX32U series)
How to perform forced cooling operation
Test run (forced cooling operation)
REQUIREMENT
Finish the forced cooling operation in a short time
because it applies excessive strength to the air
conditioner.
1
When TEMPORARY button is pushed for
10 seconds or more, “Pi!” sound is heard
and the operation changes to a forced
cooling operation. After approx. 3 minutes,
a cooling operation starts forcedly.
Check cool air starts blowing. If the operation
does not start, check wiring again.
2
To stop a test operation, push TEMPORARY
button once again (approx. 1 second).
• Check wiring / piping of the indoor and outdoor
units in forced cooling operation.
TEMPORARY
button
10
Maintenance
Before maintenance, be sure to turn off the
leakage breaker.
• Do not start the air conditioner while leaving the
panel and air filter removed.
•
If is displayed on the remote controller, maintain
the air filter.
•
Clogging of the air filter reduce cooling / heating
performance.
CAUTION
CAUTION
Cleaning of air filter
Use a vacuum cleaner to remove dust
from the filters or wash them with water.
Clean the panel and air filter with water:
Cleaning of air filters
Preparation:
Preparation:
1. Turn off the air conditioner by the remote controller.
2. Open the air intake grille.
•
Slide the button of the air intake grille inward, and
open the air intake grille slowly while holding it.
• After rinsing the air filters with water, dry them in the
shade.
• Set the air filter into the air conditioner.
• Wipe down the panel and air filter with a sponge or
towel moistened with a kitchen detergent.
(Do not use any metallic brush for cleaning.)
• Carefully rinse the panel and air filter to wash out
the detergent.
• After rinsing the panel and air filter with water,
dry it in the shade.
1. Close the air intake grille.
• Close the air intake grille, slide the knob outward,
and fix the air intake grille securely.
1. Stop the operation by remote controller.
2. Dismount the air filter.
2. “FILTER ” disappears.
1. Push the [
˄
] / [
˅
] button to select
“Filter sign reset” on the menu screen, then
push the “
Set” [
F2] button.
2. Push the “
Reset” [
F2] button.
3.
indication will be turn off.
Air intake grille
Air intake grille
Strap to
prevent falling
Air filter
Knob
Knob
If the air filters are not cleaned, it not only reduce the
cooling a performance of air conditioner but causes
a failure in the air conditioner such as water falling in
drops.
Cleaning of panel and air filter
� 24 �
47-EN
48-EN
EN
1115350171_EN,FR,ES.indd 25
19/3/2565 9:38:44