Electrical connection
•
Use the specified wires for wiring connect the terminals. Securely fix them to prevent external forces
applied to the terminals from affecting the terminals.
Incomplete connection or fixation may cause a fire or other trouble.
•
Connect earth wire. (grounding work)
Incomplete grounding cause an electric shock.
Do not connect earth wires to gas pipes, water pipes, lightning conductor or telephone earth wires.
•
Appliance shall be installed in accordance with national wiring regulations.
Capacity shortage of power circuit or incomplete installation may cause an electric shock or a fire.
1. Figure below shows the wiring connections between the indoor and outdoor units and between the indoor units
and remote controller. The wires indicated by the broken lines or dot-and-dash lines are provided at the locally.
2. Refer to the both indoor and outdoor unit wiring diagrams.
3. The power of the indoor unit is supplied from the outdoor unit.
* Use 2-core shield wire (MVVS AWG 20 to AWG 16) for the remote controller wiring in the
simultaneous twin simultaneous triple and simultaneous double twin systems to prevent noise problems.
Connect both ends of the shield wire to earth leads.
* Connect earth wires for each indoor unit in the simultaneous twin, simultaneous triple and simultaneous double
twin systems.
The remote controller wire and system interconnection wires cannot be parallel to contact each other and
cannot be stored in the same conduits. If doing so, a trouble may be caused on the control system due to
noise or other factor.
WARNING
• For power supply specifications, follow the Installation Manual of outdoor unit.
• Do not connect 208/230V~60Hz power to the terminal blocks (
A
,
B
) for control wiring.
Otherwise, the system will fail.
• Do not damage or scratch the conductive core and inner insulator of power and system interconnection wires
during peeling them.
• Perform the electric wiring so that it does not come to contact with the high-temperature part of the pipe.
The coating may melt resulting in an accident.
• Do not turn on the power of the indoor unit until vacuuming of the refrigerant pipes completes.
*Number of wire × wire size
CAUTION
CAUTION
Remote controller wiring
System interconnection wires specifications
System
interconnection
wires*
AWG 16 or more
(H07RN-F or 60245 IEC 66)
Up to
229'7"(70 m)
Remote controller wiring, remote controller inter-unit
wiring
Wire size: AWG 20 to AWG 16
Total wire length of remote controller wiring and remote
controller inter-unit wiring = L + L1 + L2 + … Ln
In case of wired type only
Up to 1640'5"(500 m)
In case of wireless type
included
Up to 1312'4"(400 m)
Total wire length of remote controller inter-unit wiring = L1 + L2 + … Ln
Up to 656'2"(200 m)
Remote controller inter-unit wiring
(Max. 8 units)
L1
L
L2
Ln
Remote
controller
wiring
Remote
controller
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Wiring between indoor unit and outdoor unit
Wiring diagram
Simultaneous triple and double twin system
Single system
Remote controller
Remote controller
Remote controller
Remote controller
inter-unit wiring
Remote controller wiring
Remote controller
wiring
Remote controller
inter-unit wiring
Indoor power
inter-unit wiring
Indoor power
inter-unit wiring
Indoor power
inter-unit wiring
Remote controller
inter-unit wiring
Remote controller
inter-unit wiring
Remote controller wiring
Indoor side
Indoor side
Indoor side
Indoor side
Indoor side
Indoor side
Triple
Double twin
Indoor
side
Indoor power
inter-unit wiring
Outdoor side
Outdoor side
Outdoor side
Power supply
Power supply
Power supply
System interconnection
wires
System
interconnection wires
System interconnection wires
Simultaneous twin system
L1
L1
L1
L1
L2
L2
L2
L2
S
S
S
S
� 14 �
27-EN
28-EN
EN
1115350171_EN,FR,ES.indd 15
19/3/2565 9:37:47