– 64 –
No.
Part name
Pulse Modulating
Valve (PMV) coi
Procedure
1. Detachment
1) Perform works of items 1 of
and 1 of
.
2) Remove the side cabinet (Right).
3) Pull upward the coil, and remove the
coil from PMV body.
2. Attachment
1) Fix the projection for coil positioning
surely to pipe of PMV body and fix it.
PMV coil
Remarks
Fan guard
1. Detachment
1) Perform works of items 1 of
and 1 of
.
REQUIREMENT
Perform works on a corrugated card-
board, cloth, etc. to prevent flaw on the
product.
2) Remove the front cabinet, and then put
it downward on the floor.
3) Take off the hooking claw of the fan
guard by pushing with minus screw-
driver, etc.
2. Attachment
1) Insert the hooking claw of the fan guard
into hole of the front cabinet. Fix claw
while pushing the hooking claws
(10 positions) with hands.
REQUIREMENT
Check that all the hooking claws are
fixed to the specified positions.
P.M.V. coil
Minus screwdriver
Hooking claw
Front cabinet
Front cabinet
Fan guard