Part names and functions of the remote 

controller

Remote controller model name: RBC-ASCU1

LCD back-light lights for 15 seconds during remote controller operation.
All indicators are displayed in the display example below.
Actually, only the selected options will be displayed.

Operations

1

ON/OFF button

Turns on the unit when pushed, and turns off when pushed again.

2

Setting button

Sets setting temperature at the normal mode.
Changes each setting at the Operation mode, the Fan speed mode or the Wind direction mode.

3

OFF timer button

Setting the OFF timer.

4

Menu button

Selects the Operation mode select, the Fan speed select or the Wind direction select.
Each time you push the button, indicator is displayed as followings.
• The Fan speed select or the Wind direction select is not displayed depending on indoor unit models.

1

2

3

4

Operation lamp

Lights during operations.

Blinks when a check occurs or the 

protective device activates.

Normal operation 

mode

Operation mode 

select

Fan speed select

Wind direction 

select

Indicators

All icons on the display are shown for this explanation. Operations are not accepted when “SETTING” is flashing.

1

Operation mode indicator

Indicates the operation mode selected.

2

Central control indicator

Displayed when the air conditioner is controlled 
centrally and used with central control devices 
such as the central remote controller.
If the use of the remote controller is prohibited by 
the central control, 

 

blinks when the ON/OFF, 

MODE, or TEMP. button on the remote controller 
is pushed, and the buttons do not function.
(Settings that can be configured on the remote 
controller differ depending on the mode of the 
central control. For details, read the Owner’s 
Manual of the central remote controller.)

3

Setting indicator

Indicates that the model is being checked 
automatically after a breaker is thrown or some 
other occurrence.

4

Service indicator

Displayed while the protective device works or a 
check occurs.

5

Test run indicator

Displayed during test run.

6

Temperature setting indicator

The selected set temperature is displayed.

7

Swing indicator

Displayed during up/down movement of the 
louver.

8

Louver position indicator

Indicates the louver position.

9

Louver lock indicator

Displayed when there is a louver-locked unit.

10

Fan speed indicator

Indicates the selected fan speed

11

OFF timer indicator

When a trouble occurs, a check code is displayed.

12

Pre-heat indicator

Displayed when the heating mode is energized or 
defrost cycle is initiated.
While this indication is displayed, the indoor fan 
stops or operate in fan mode.

13

Remote controller sensor indicator

Displayed while the sensor of the remote controller 
is used.

14

Notice display

Displayed while notice code occurs.
For details, contact your dealer (distributor). 

15

No function display

Displayed when the function requested is not 
available on that model.

2

3 4

5

6

10

14

11

12

15

7

8

1

9

13

Auto
Low
Low +
Medium

High
Fix

13-EN

14-EN

Содержание RAV-HM1101UT-E

Страница 1: ...AIR CONDITIONER SPLIT TYPE Owner s Manual R32 Indoor Unit 4 way Cassette type RAV HM561UT E RAV HM801UT E RAV HM1101UT E RAV HM1401UT E Model name For commercial use English ...

Страница 2: ...n individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she i...

Страница 3: ...e to property indicates damage extending to buildings household effects domestic livestock and pets WARNING Risk of fire Read the OWNER S MANUAL carefully before operation Service personnel are required to carefully read the OWNER S MANUAL and INSTALLATION MANUAL before operation Further information is available in the OWNER S MANUAL INSTALLATION MANUAL and the like Warning indications on the air ...

Страница 4: ...itioner Under no circumstances must this work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the installer explain about the circuit breaker positions In the event that trouble has occurred in the air conditioner set the circuit breaker to the OFF position an...

Страница 5: ...erwise injury may result as the fan is rotating at high speed inside the unit Repairs When you have noticed that some kind of trouble such as when a check display has appeared there is a smell of burning abnormal sounds are heard the air conditioner fails to cool or heat or water is leaking has occurred in the air conditioner do not touch the air conditioner yourself but set the circuit breaker to...

Страница 6: ...rate it within the range of the operating temperature specified in the instructions Otherwise it may cause a malfunction or water leak from the unit Prevent any liquid from falling into the remote controller Do not spill juice water or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deterio...

Страница 7: ...lity Don t handle with packing band or may get injured in case of broken band Stacking notice In case that cardboard boxes protrude out of pallet when stacking Lay a 10 mm thick plywood over the pallet 8 8 cartons 2 Part names Indoor unit Hook Hook to open and close the air intake grille Air discharge discharge louver Change the direction of the wind blowing out when warming or cooling the room Ai...

Страница 8: ...er If the use of the remote controller is prohibited by the central control blinks when the ON OFF MODE or TEMP button on the remote controller is pushed and the buttons do not function Settings that can be configured on the remote controller differ depending on the mode of the central control For details read the Owner s Manual of the central remote controller 3 Setting indicator Indicates that t...

Страница 9: ...is a demand for cooling unit will start approximately 1 minute after mode is selected When the room temperature reaches the set temperature the outdoor unit stops and the indoor unit fan runs at extremely low speed Heating If there is a demand for heating unit will start approximately 3 to 5 minutes after the mode is selected After the heating operation has stopped fan may continue to run for appr...

Страница 10: ...n the surface of the air discharge or louver and may drop down NOTE If pointing horizontally for heating the room temperature may be uneven Do not handle the louver manually Doing so may cause a failure Use the remote controller to adjust the angle To set the louver direction and auto swing 1 Push the Menu button several times and select the wind direction mode to blink the wind direction 2 Push t...

Страница 11: ...Information The following functions require a connection with the RBC AMTU and RBC AMSU remote controller For details consult the dealer where you purchased this product Individual unit selection during group operation Individual setting of louver position wind direction Swing type setting Louver lock no swing setting 7 Maintenance WARNING Cleaning the air filter and other parts of the air filter ...

Страница 12: ...ning the unit turn off the circuit breaker and inform the dealer where you purchased the product of the product number and symptom Do not attempt to repair the unit by yourself as doing so is dangerous If the check indicator etc is displayed on the remote controller LCD inform the dealer of its content as well If any of the following occur stop running the unit immediately turn off the circuit bre...

Страница 13: ...g operation defrosting starts automatically for approximately 2 to 10 minutes to maintain the heating capacity The fans in both indoor and outdoor units will stop during the defrosting operation During the defrosting operation the fan of the indoor unit outdoor unit stops and the louver of the indoor unit closes During the defrosting operation the defrosted water will be drained from the bottom pl...

Страница 14: ...g equipment etc that disturbs discharge air Turbulent airflow may reduce the performance or disable devices Do not use the air conditioner for special purposes such as preserving food precision instruments or art objects or where breeding animals or growing plants are kept This may degrade the quality of preserved materials Do not install the air conditioner over an object that must not get wet Co...

Страница 15: ...or Manager Quality Assurance Service Engineering Dept Date 07 April 2022 Place Issued Japan Declaration of Conformity NOTE This declaration becomes invalid if technical or operational modifications are introduced without the manufacturer s consent Manufacturer TOSHIBA CARRIER CORPORATION 336 Tadehara Fuji shi Shizuoka ken 416 8521 JAPAN TCF holder TOSHIBA CARRIER UK LTD Porsham Close Belliver Indu...

Страница 16: ...EH99970801 DH91308101 ...

Отзывы: