background image

– 1 –

Original instruction

Contents

1 Precautions for safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2 Part names  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . 6

3 Part names and functions of the remote controller  . . . . . . . . . . . . . . . . . . . . . . . . . . 7

4 Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

5 OFF timer operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

6 Adjustment of wind direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

7 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

9 Operations and performance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

10 Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

11 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Thank you very much for purchasing TOSHIBA Air Conditioner.
Please read this owner’s manual carefully before using your Air Conditioner.

• Be sure to obtain the “Owner’s manual” and “Installation manual” from constructor (or dealer).
• Request to constructor or dealer

Please clearly explain the contents of the Owner’s manual and hand over it.

ADOPTION OF R32 REFRIGERANT

This Air Conditioner has adopted a refrigerant HFC (R32) which does not destroy the ozone layer.

This appliance can be used by children aged from 8 years and 
above and persons with reduced physical, sensory or mental 
capabilities or lack of experience and knowledge if they have 
been given supervision or instruction concerning use of the 
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user 
maintenance shall not be made by children without supervision.

Thank you for purchasing this Toshiba air conditioner.
Please read carefully through these instructions that contain important information which complies with the 
“Machinery Directive 2006 / 42 / EC”, and ensure that you understand them.
After reading these instructions, be sure to keep them in a safe place together with the Owner’s Manual and 
Installation Manual supplied with your product.

Generic Denomination: Air Conditioner

Definition of Qualified Installer or Qualified Service Person

The air conditioner must be installed, maintained, repaired and removed by a qualified installer or qualified service 
person. When any of these jobs is to be done, ask a qualified installer or qualified service person to do them.
A qualified installer or qualified service person is an agent who has the qualifications and knowledge described in 
the table below.

Agent

Qualifications and knowledge which the agent must have

Qualified installer
(*1) 

• The qualified installer is a person who installs, maintains, relocates and removes the air conditioners 

made by Toshiba Carrier Corporation. He or she has been trained to install, maintain, relocate and 

remove the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been 

instructed in such operations by an individual or individuals who have been trained and is thus 

thoroughly acquainted with the knowledge related to these operations.

• The qualified installer who is allowed to do the electrical work involved in installation, relocation and 

removal has the qualifications pertaining to this electrical work as stipulated by the local laws and 

regulations, and he or she is a person who has been trained in matters relating to electrical work on 

the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been 

instructed in such matters by an individual or individuals who have been trained and is thus thoroughly 

acquainted with the knowledge related to this work.

• The qualified installer who is allowed to do the refrigerant handling and piping work involved in 

installation, relocation and removal has the qualifications pertaining to this refrigerant handling and 

piping work as stipulated by the local laws and regulations, and he or she is a person who has been 

trained in matters relating to refrigerant handling and piping work on the air conditioners made by 

Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such matters by an 

individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge 

related to this work.

• The qualified installer who is allowed to work at heights has been trained in matters relating to working 

at heights with the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she 

has been instructed in such matters by an individual or individuals who have been trained and is thus 

thoroughly acquainted with the knowledge related to this work.

Qualified service 

person (*1) 

• The qualified service person is a person who installs, repairs, maintains, relocates and removes the 

air conditioners made by Toshiba Carrier Corporation. He or she has been trained to install, repair, 

maintain, relocate and remove the air conditioners made by Toshiba Carrier Corporation or, 

alternatively, he or she has been instructed in such operations by an individual or individuals who have 

been trained and is thus thoroughly acquainted with the knowledge related to these operations.

• The qualified service person who is allowed to do the electrical work involved in installation, repair, 

relocation and removal has the qualifications pertaining to this electrical work as stipulated by the local 

laws and regulations, and he or she is a person who has been trained in matters relating to electrical 

work on the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been 

instructed in such matters by an individual or individuals who have been trained and is thus thoroughly 

acquainted with the knowledge related to this work.

• The qualified service person who is allowed to do the refrigerant handling and piping work involved in 

installation, repair, relocation and removal has the qualifications pertaining to this refrigerant handling 

and piping work as stipulated by the local laws and regulations, and he or she is a person who has 

been trained in matters relating to refrigerant handling and piping work on the air conditioners made 

by Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such matters by an 

individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge 

related to this work.

• The qualified service person who is allowed to work at heights has been trained in matters relating to 

working at heights with the air conditioners made by Toshiba Carrier Corporation or, alternatively, he 

or she has been instructed in such matters by an individual or individuals who have been trained and 

is thus thoroughly acquainted with the knowledge related to this work.

1-EN

2-EN

Содержание RAV-HM1101UT-E

Страница 1: ...AIR CONDITIONER SPLIT TYPE Owner s Manual R32 Indoor Unit 4 way Cassette type RAV HM561UT E RAV HM801UT E RAV HM1101UT E RAV HM1401UT E Model name For commercial use English ...

Страница 2: ...n individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she i...

Страница 3: ...e to property indicates damage extending to buildings household effects domestic livestock and pets WARNING Risk of fire Read the OWNER S MANUAL carefully before operation Service personnel are required to carefully read the OWNER S MANUAL and INSTALLATION MANUAL before operation Further information is available in the OWNER S MANUAL INSTALLATION MANUAL and the like Warning indications on the air ...

Страница 4: ...itioner Under no circumstances must this work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the installer explain about the circuit breaker positions In the event that trouble has occurred in the air conditioner set the circuit breaker to the OFF position an...

Страница 5: ...erwise injury may result as the fan is rotating at high speed inside the unit Repairs When you have noticed that some kind of trouble such as when a check display has appeared there is a smell of burning abnormal sounds are heard the air conditioner fails to cool or heat or water is leaking has occurred in the air conditioner do not touch the air conditioner yourself but set the circuit breaker to...

Страница 6: ...rate it within the range of the operating temperature specified in the instructions Otherwise it may cause a malfunction or water leak from the unit Prevent any liquid from falling into the remote controller Do not spill juice water or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deterio...

Страница 7: ...lity Don t handle with packing band or may get injured in case of broken band Stacking notice In case that cardboard boxes protrude out of pallet when stacking Lay a 10 mm thick plywood over the pallet 8 8 cartons 2 Part names Indoor unit Hook Hook to open and close the air intake grille Air discharge discharge louver Change the direction of the wind blowing out when warming or cooling the room Ai...

Страница 8: ...er If the use of the remote controller is prohibited by the central control blinks when the ON OFF MODE or TEMP button on the remote controller is pushed and the buttons do not function Settings that can be configured on the remote controller differ depending on the mode of the central control For details read the Owner s Manual of the central remote controller 3 Setting indicator Indicates that t...

Страница 9: ...is a demand for cooling unit will start approximately 1 minute after mode is selected When the room temperature reaches the set temperature the outdoor unit stops and the indoor unit fan runs at extremely low speed Heating If there is a demand for heating unit will start approximately 3 to 5 minutes after the mode is selected After the heating operation has stopped fan may continue to run for appr...

Страница 10: ...n the surface of the air discharge or louver and may drop down NOTE If pointing horizontally for heating the room temperature may be uneven Do not handle the louver manually Doing so may cause a failure Use the remote controller to adjust the angle To set the louver direction and auto swing 1 Push the Menu button several times and select the wind direction mode to blink the wind direction 2 Push t...

Страница 11: ...Information The following functions require a connection with the RBC AMTU and RBC AMSU remote controller For details consult the dealer where you purchased this product Individual unit selection during group operation Individual setting of louver position wind direction Swing type setting Louver lock no swing setting 7 Maintenance WARNING Cleaning the air filter and other parts of the air filter ...

Страница 12: ...ning the unit turn off the circuit breaker and inform the dealer where you purchased the product of the product number and symptom Do not attempt to repair the unit by yourself as doing so is dangerous If the check indicator etc is displayed on the remote controller LCD inform the dealer of its content as well If any of the following occur stop running the unit immediately turn off the circuit bre...

Страница 13: ...g operation defrosting starts automatically for approximately 2 to 10 minutes to maintain the heating capacity The fans in both indoor and outdoor units will stop during the defrosting operation During the defrosting operation the fan of the indoor unit outdoor unit stops and the louver of the indoor unit closes During the defrosting operation the defrosted water will be drained from the bottom pl...

Страница 14: ...g equipment etc that disturbs discharge air Turbulent airflow may reduce the performance or disable devices Do not use the air conditioner for special purposes such as preserving food precision instruments or art objects or where breeding animals or growing plants are kept This may degrade the quality of preserved materials Do not install the air conditioner over an object that must not get wet Co...

Страница 15: ...or Manager Quality Assurance Service Engineering Dept Date 07 April 2022 Place Issued Japan Declaration of Conformity NOTE This declaration becomes invalid if technical or operational modifications are introduced without the manufacturer s consent Manufacturer TOSHIBA CARRIER CORPORATION 336 Tadehara Fuji shi Shizuoka ken 416 8521 JAPAN TCF holder TOSHIBA CARRIER UK LTD Porsham Close Belliver Indu...

Страница 16: ...EH99970801 DH91308101 ...

Отзывы: