– 9 –
5
OFF timer operation
OFF timer: The indoor unit stops when the set time is reached.
1
OFF timer button
Push the OFF timer button during air conditioning operation.
• “
” and “OFF” light and “SETTING” and timer indicator flash.
2
Select the OFF timer time
Push the setting button to set the time.
• The OFF timer time can be set to 0.5h (30 min), 1h, 2h,
∙
∙
∙
up to 24h.
• If you do not push any button for 30s, the OFF timer setting will be cancelled.
3
Push the OFF timer button
“SETTING” disappears, the timer indicator changes from flashing to lighting, and the OFF timer starts.
• The timer indicator on the OFF timer operation is displayed with countdown.
■
Cancelling the timer
1
Push the OFF timer button
The timer indicator disappears.
NOTE
Even if air conditioning is turned on or off with the ON/OFF button during OFF timer operation, the OFF timer operation
continues.
1,3
2
6
Adjustment of wind direction
To improve the cooling / heating performance,
change the louver angle for each operation.
Air characteristics: Cool air falls, and warm air
rises.
CAUTION
CAUTION
Point the louver horizontally during cooling
If pointing downward for cooling, dew may form on the
surface of the air discharge or louver and may drop
down.
NOTE
• If pointing horizontally for heating, the room
temperature may be uneven.
• Do not handle the louver manually. Doing so may
cause a failure. Use the remote controller to adjust the
angle.
To set the louver direction and auto swing
1
Push the Menu button several times and select
the wind direction mode to blink the wind
direction.
2
Push the setting button several times to display
the louver direction as shown in the figure
below.
• If you do not push any button for 30s, the wind
direction mode finishes.
▼
For heating
The louver can be adjusted to six steps.
Point the louver downward. If not pointing downward,
hot air may not reach the floor.
▼
For cooling
The louver can be adjusted to four steps.
Point the louver horizontally. If pointing downward, dew
may form on the surface of the air discharge port and
may drop down.
If a louver lock setup is carried out in the position of (1),
fan speed will be restricted for prevention of ceiling
contamination.
▼
For fan
The louver can be adjusted to six steps.
Select a wind direction.
■
Auto swing
The SWING
indicator is displayed and the louver
begins swinging.
Initial
(1)
(2)
(3)
(4)
(5)
(6)
Operation mode
Available directions
HEAT, FAN
(1)
↔
(2)
↔
(3)
↔
(4)
↔
(5)
↔
(6)
(Swing)
Initial
(1)
(2)
(3)
(4)
Operation mode
Available directions
COOL, DRY
(1)
↔
(2)
↔
(3)
↔
(4)
(Swing)
Repeat
17-EN
18-EN