– 12 –

Confirmation and check

Troubleshooting history and confirmation

You can check the troubleshooting history with the following procedure if a problem occurs with the air conditioner. 
(The troubleshooting history records up to 4 incidents.)
You can check it during operation or when operation is stopped.
• If you check the troubleshooting history during OFF timer operation, the OFF timer will be cancelled. 

If a problem occurs with the air 
conditioner, the OFF timer indicator 
alternately shows the check code and 
the indoor Unit No. in which the 
problem occurred.

Procedure

Description of operation

1

Push the OFF timer button for over 10 seconds and the 
indicators appear as an image indicating the 
troubleshooting history mode has been entered. If 
[

Service check] is displayed, the mode enters in the 

troubleshooting history mode.
•  [01: Order of troubleshooting history] appears in the 

temperature indicator.

• The OFF timer indicator alternately shows the [check 

code] and the [indoor Unit No.] in which the problem 
occurred. 

2

Each time the setting button is pushed, the recorded 
troubleshooting history is displayed in sequence.
The troubleshooting history appears in order from [01] 
(newest) to [04] (oldest).

CAUTION

CAUTION

In the troubleshooting history mode, DO NOT push the 
Menu button for over 10 seconds, doing so deletes the 
entire troubleshooting history of the indoor unit.

3

After you have finished checking, push the ON/OFF button 
to return to the regular mode.
• If the air conditioner is operating, it remains operated 

even after the ON/OFF button has been pushed.
To stop its operation, push the ON/OFF button again.

Check code

The indoor Unit No. in which 

the problem occurred.

3

1

2

9

Operations and performance

Check before running

• Check whether the earth wire is cut or disconnected.
• Check whether the air filter is installed.
• Turn on the circuit breaker 12 hours or more before starting 

operation.

3 minutes protection function

3-minutes protection function prevents the air conditioner 
from starting for initial 3 minutes after the main power switch 
/ circuit breaker is turned on for re-starting the air conditioner.

Power failure

Power failure during operation will stop the unit completely.
• To restart the operation, push the ON / OFF button on the 

remote controller.

• Lightning or a wireless car telephone operating nearby 

may cause the unit to malfunction. Turn off the main power 
switch or circuit breaker and then turn them on again. Push 
the ON / OFF button on the remote controller to restart.

Defrosting operation

If the outdoor unit is frosted during the heating operation, 
defrosting starts automatically (for approximately 2 to 10 
minutes) to maintain the heating capacity.
• The fans in both indoor and outdoor units will stop during 

the defrosting operation.

• During the defrosting operation, the fan of the indoor unit / 

outdoor unit stops and the louver of the indoor unit closes.

• During the defrosting operation, the defrosted water will be 

drained from the bottom plate of the outdoor unit.

Heating capacity

In the heating operation, the heat is absorbed from the 
outside and brought into the room. This way of heating is 
called heat pump system. When the outside temperature is 
too low, it is recommended to use another heating apparatus 
in combination with the air conditioner.

Protective device

• Stops operation when the air-conditioner is overloaded.
• If the protective device is activated, the unit stops running, 

and the operation indicator and check indicator on the 
remote controller blink.

If the protective device is activated

• Turn off the circuit breaker and perform a checkup.

Continued running may cause a malfunction.

• Check whether the air filter is installed. If not, the heat 

exchanger may be clogged with dust and water leakage 
may occur.

During cooling

• The air intake or discharge of the outdoor unit is 

clogged.

• Strong wind continuously blows against the discharge of 

the outdoor unit.

During heating

• The air filter is clogged with a large amount of dust.
• The air intake or discharge of the indoor unit is clogged.

Do not turn off the circuit breaker

• During the air-conditioning season, leave the circuit 

breaker turned on, and use the ON / OFF key on the 
remote controller.

Attention to snowfall and freeze on the 
outdoor unit

• In snowy areas, the air intake and air discharge of the 

outdoor unit are often covered with snow or frozen up.
If snow or freeze on the outdoor unit is left as it is, it may 
cause machine failure or poor warming.

• In cold areas, pay attention to the drain hose so that it 

perfectly drains water without water remaining inside for 
freeze prevention. If water freezes in the drain hose or 
inside the outdoor unit, it may cause machine failure or 
poor warming.

Air conditioner operating conditions

For proper performance, operate the air conditioner under the following temperature conditions:
Refer to the combined outdoor unit installation manual for details about the outdoor temperature.

If air conditioner is used outside of the above conditions, safety protection may work.

Cooling operation

Room temperature

: 21 °C to 32 °C (Dry bulb temp.), 15 °C to 24 °C (Wet bulb temp.)

[CAUTION]

Room relative humidity – less than 80%. If the air conditioner operates in excess of this 

figure, the surface of the air conditioner may cause dewing.

Heating operation

Room temperature

: 15 °C to 28 °C (Dry bulb temp.)

23-EN

24-EN

Содержание RAV-HM1101UT-E

Страница 1: ...AIR CONDITIONER SPLIT TYPE Owner s Manual R32 Indoor Unit 4 way Cassette type RAV HM561UT E RAV HM801UT E RAV HM1101UT E RAV HM1401UT E Model name For commercial use English ...

Страница 2: ...n individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she i...

Страница 3: ...e to property indicates damage extending to buildings household effects domestic livestock and pets WARNING Risk of fire Read the OWNER S MANUAL carefully before operation Service personnel are required to carefully read the OWNER S MANUAL and INSTALLATION MANUAL before operation Further information is available in the OWNER S MANUAL INSTALLATION MANUAL and the like Warning indications on the air ...

Страница 4: ...itioner Under no circumstances must this work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the installer explain about the circuit breaker positions In the event that trouble has occurred in the air conditioner set the circuit breaker to the OFF position an...

Страница 5: ...erwise injury may result as the fan is rotating at high speed inside the unit Repairs When you have noticed that some kind of trouble such as when a check display has appeared there is a smell of burning abnormal sounds are heard the air conditioner fails to cool or heat or water is leaking has occurred in the air conditioner do not touch the air conditioner yourself but set the circuit breaker to...

Страница 6: ...rate it within the range of the operating temperature specified in the instructions Otherwise it may cause a malfunction or water leak from the unit Prevent any liquid from falling into the remote controller Do not spill juice water or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deterio...

Страница 7: ...lity Don t handle with packing band or may get injured in case of broken band Stacking notice In case that cardboard boxes protrude out of pallet when stacking Lay a 10 mm thick plywood over the pallet 8 8 cartons 2 Part names Indoor unit Hook Hook to open and close the air intake grille Air discharge discharge louver Change the direction of the wind blowing out when warming or cooling the room Ai...

Страница 8: ...er If the use of the remote controller is prohibited by the central control blinks when the ON OFF MODE or TEMP button on the remote controller is pushed and the buttons do not function Settings that can be configured on the remote controller differ depending on the mode of the central control For details read the Owner s Manual of the central remote controller 3 Setting indicator Indicates that t...

Страница 9: ...is a demand for cooling unit will start approximately 1 minute after mode is selected When the room temperature reaches the set temperature the outdoor unit stops and the indoor unit fan runs at extremely low speed Heating If there is a demand for heating unit will start approximately 3 to 5 minutes after the mode is selected After the heating operation has stopped fan may continue to run for appr...

Страница 10: ...n the surface of the air discharge or louver and may drop down NOTE If pointing horizontally for heating the room temperature may be uneven Do not handle the louver manually Doing so may cause a failure Use the remote controller to adjust the angle To set the louver direction and auto swing 1 Push the Menu button several times and select the wind direction mode to blink the wind direction 2 Push t...

Страница 11: ...Information The following functions require a connection with the RBC AMTU and RBC AMSU remote controller For details consult the dealer where you purchased this product Individual unit selection during group operation Individual setting of louver position wind direction Swing type setting Louver lock no swing setting 7 Maintenance WARNING Cleaning the air filter and other parts of the air filter ...

Страница 12: ...ning the unit turn off the circuit breaker and inform the dealer where you purchased the product of the product number and symptom Do not attempt to repair the unit by yourself as doing so is dangerous If the check indicator etc is displayed on the remote controller LCD inform the dealer of its content as well If any of the following occur stop running the unit immediately turn off the circuit bre...

Страница 13: ...g operation defrosting starts automatically for approximately 2 to 10 minutes to maintain the heating capacity The fans in both indoor and outdoor units will stop during the defrosting operation During the defrosting operation the fan of the indoor unit outdoor unit stops and the louver of the indoor unit closes During the defrosting operation the defrosted water will be drained from the bottom pl...

Страница 14: ...g equipment etc that disturbs discharge air Turbulent airflow may reduce the performance or disable devices Do not use the air conditioner for special purposes such as preserving food precision instruments or art objects or where breeding animals or growing plants are kept This may degrade the quality of preserved materials Do not install the air conditioner over an object that must not get wet Co...

Страница 15: ...or Manager Quality Assurance Service Engineering Dept Date 07 April 2022 Place Issued Japan Declaration of Conformity NOTE This declaration becomes invalid if technical or operational modifications are introduced without the manufacturer s consent Manufacturer TOSHIBA CARRIER CORPORATION 336 Tadehara Fuji shi Shizuoka ken 416 8521 JAPAN TCF holder TOSHIBA CARRIER UK LTD Porsham Close Belliver Indu...

Страница 16: ...EH99970801 DH91308101 ...

Отзывы: