background image

– 8 –

4

Operation

When you use the air conditioner for the first time or change the settings, follow the procedures below. From next 
time, pushing the ON/OFF button starts running of the air conditioner with the chosen settings.

Standby

Operations are not accepted when “SETTING” is blinking.

REQUIREMENT

• Keep the power switch turned on during use.
• When you resume using the air conditioner after a long period of disuse, turn on the power switch at least 12 hours 

before starting running.

• When the power is turned on, it takes about 1 minute before the remote controller becomes operable.

This is not a malfunction.

Running operation

Some operation modes are not available depending on the type of indoor unit.

1

ON/OFF button

Push this button to light the operation lamp and 
start operations.

When heating

• The heated air comes out after a 3 to 5 minutes 

of pre-heating with the indoor fan kept turned 
off.

2

Select the operation mode

Push the Menu button several times to select the 
operation mode.
• The current operation mode flashes.

Each time you push the setting button, the 
operation mode and its icon change in the 
following order:

• If you do not push any button for 30s, the 

operation mode finishes.

3

Select the fan speed

Push the Menu button several times to select the 
fan speed mode.
• The current fan speed indicator flashes.
Each time you push the setting button, the fan 
speed mode and its indication change in the 
following order:
• A selectable fan speed differs depending on 

indoor units to be connected.

• “

Auto” cannot be selected at the Fan 

mode.

• If you do not push any button for 30s, the fan 

speed mode finishes.

4

Select the temperature

Push the setting button to adjust the temperature.
• The temperature setting range is 18.0 °C to 

29.0 °C.

• The temperature can be set in steps of 0.5 °C.

Menu button

Setting button

ON/OFF button

Heat

Dry

Cool

Fan

(Dehumidify)

Auto

NOTE

Auto Changeover

• When in Auto Mode, the unit selects the operating mode (cooling, heating or fan only) based on the user set point 

temperature.

• If the Auto mode is uncomfortable, you can select the desired conditions manually.

Cooling

• If there is a demand for cooling, unit will start approximately 1 minute after mode is selected.
• When the room temperature reaches the set temperature, the outdoor unit stops and the indoor unit fan runs at extremely 

low speed.

Heating

• If there is a demand for heating, unit will start approximately 3 to 5 minutes after the mode is selected.
• After the heating operation has stopped, fan may continue to run for approx. 30 seconds.
• When the room temperature reaches the set temperature, the outdoor unit stops and the indoor unit fan runs at extremely 

low speed.

• During defrost operation, the fan stops so that cool air is not discharged. (“

” Pre-heat is displayed.)

When restarting the operation after stop

When the unit is attempted to restart immediately after it was stopped, the unit can not start for approx. 3 minutes this is to 
protect the compressor.

8 °C Operation (For object pre-heating)

The air conditioner can control the heating temperature to about 8 °C in the heating mode.

The 8 °C heating operation requires settings with the wired remote controller. Ask the installer or dealer for the settings 
according to the installation manual of the indoor unit.

Start

1

Set the displayed temperature to 18 °C in the heating mode by pushing [

] setting button.

2

Set the displayed temperature to 8 °C by pushing [

] setting button for at least four seconds.

Stop

1

Set the displayed temperature to 18 °C by pushing [

] setting button.

• The air conditioner returns to the normal Heat mode. Select a desired temperature and operation mode.

NOTE

• The discharged air temperature is lower than that in the normal heating operation.
• The room temperature may not be heated evenly depending on the remote controller installation location.
• The room temperature may not reach 8 °C depending on the room size or the installation conditions.
• Setting for fan speed is available during the 8 °C heating operation.

The 8 °C heating operation is cancelled in the following cases.
•When operation is stopped with ON/OFF button.
•When another operation mode is selected.
•When temperature setting or operation mode is changed or operation is started / stopped by the wireless remote controller 

or the central control remote controller.

• When this operation mode is used, observe proper operating hours and periodic maintenance by service staff is 

recommended.

15-EN

16-EN

Содержание RAV-HM1101UT-E

Страница 1: ...AIR CONDITIONER SPLIT TYPE Owner s Manual R32 Indoor Unit 4 way Cassette type RAV HM561UT E RAV HM801UT E RAV HM1101UT E RAV HM1401UT E Model name For commercial use English ...

Страница 2: ...n individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she i...

Страница 3: ...e to property indicates damage extending to buildings household effects domestic livestock and pets WARNING Risk of fire Read the OWNER S MANUAL carefully before operation Service personnel are required to carefully read the OWNER S MANUAL and INSTALLATION MANUAL before operation Further information is available in the OWNER S MANUAL INSTALLATION MANUAL and the like Warning indications on the air ...

Страница 4: ...itioner Under no circumstances must this work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the installer explain about the circuit breaker positions In the event that trouble has occurred in the air conditioner set the circuit breaker to the OFF position an...

Страница 5: ...erwise injury may result as the fan is rotating at high speed inside the unit Repairs When you have noticed that some kind of trouble such as when a check display has appeared there is a smell of burning abnormal sounds are heard the air conditioner fails to cool or heat or water is leaking has occurred in the air conditioner do not touch the air conditioner yourself but set the circuit breaker to...

Страница 6: ...rate it within the range of the operating temperature specified in the instructions Otherwise it may cause a malfunction or water leak from the unit Prevent any liquid from falling into the remote controller Do not spill juice water or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deterio...

Страница 7: ...lity Don t handle with packing band or may get injured in case of broken band Stacking notice In case that cardboard boxes protrude out of pallet when stacking Lay a 10 mm thick plywood over the pallet 8 8 cartons 2 Part names Indoor unit Hook Hook to open and close the air intake grille Air discharge discharge louver Change the direction of the wind blowing out when warming or cooling the room Ai...

Страница 8: ...er If the use of the remote controller is prohibited by the central control blinks when the ON OFF MODE or TEMP button on the remote controller is pushed and the buttons do not function Settings that can be configured on the remote controller differ depending on the mode of the central control For details read the Owner s Manual of the central remote controller 3 Setting indicator Indicates that t...

Страница 9: ...is a demand for cooling unit will start approximately 1 minute after mode is selected When the room temperature reaches the set temperature the outdoor unit stops and the indoor unit fan runs at extremely low speed Heating If there is a demand for heating unit will start approximately 3 to 5 minutes after the mode is selected After the heating operation has stopped fan may continue to run for appr...

Страница 10: ...n the surface of the air discharge or louver and may drop down NOTE If pointing horizontally for heating the room temperature may be uneven Do not handle the louver manually Doing so may cause a failure Use the remote controller to adjust the angle To set the louver direction and auto swing 1 Push the Menu button several times and select the wind direction mode to blink the wind direction 2 Push t...

Страница 11: ...Information The following functions require a connection with the RBC AMTU and RBC AMSU remote controller For details consult the dealer where you purchased this product Individual unit selection during group operation Individual setting of louver position wind direction Swing type setting Louver lock no swing setting 7 Maintenance WARNING Cleaning the air filter and other parts of the air filter ...

Страница 12: ...ning the unit turn off the circuit breaker and inform the dealer where you purchased the product of the product number and symptom Do not attempt to repair the unit by yourself as doing so is dangerous If the check indicator etc is displayed on the remote controller LCD inform the dealer of its content as well If any of the following occur stop running the unit immediately turn off the circuit bre...

Страница 13: ...g operation defrosting starts automatically for approximately 2 to 10 minutes to maintain the heating capacity The fans in both indoor and outdoor units will stop during the defrosting operation During the defrosting operation the fan of the indoor unit outdoor unit stops and the louver of the indoor unit closes During the defrosting operation the defrosted water will be drained from the bottom pl...

Страница 14: ...g equipment etc that disturbs discharge air Turbulent airflow may reduce the performance or disable devices Do not use the air conditioner for special purposes such as preserving food precision instruments or art objects or where breeding animals or growing plants are kept This may degrade the quality of preserved materials Do not install the air conditioner over an object that must not get wet Co...

Страница 15: ...or Manager Quality Assurance Service Engineering Dept Date 07 April 2022 Place Issued Japan Declaration of Conformity NOTE This declaration becomes invalid if technical or operational modifications are introduced without the manufacturer s consent Manufacturer TOSHIBA CARRIER CORPORATION 336 Tadehara Fuji shi Shizuoka ken 416 8521 JAPAN TCF holder TOSHIBA CARRIER UK LTD Porsham Close Belliver Indu...

Страница 16: ...EH99970801 DH91308101 ...