background image

18-EN

17-EN

– 9 –

NOTE

Auto Changeover

 

y

When in Auto Mode, the unit selects the operating mode (cooling, heating or fan only) based on the user set 
point temperature.

•  If the Auto mode is uncomfortable, you can select the desired conditions manually.

Cooling

•  If there is a demand for cooling, unit will start approximately 1 minute after mode is selected.
•  When the room temperature reaches the set temperature, the outdoor unit stops and the indoor unit fan runs at 

extremely low speed.

Heating

•  If there is a demand for heating, unit will start approximately 3 to 5 minutes after the mode is selected.
•  After the heating operation has stopped, fan may continue to run for approx. 30 seconds.
•  When the room temperature reaches the set temperature, the outdoor unit stops and the indoor unit fan runs at 

extremely low speed.

•  During defrost operation, the fan stops so that cool air is not discharged. (“   ” Pre-heat is displayed.)

When operation is restarted after stop

When the unit is attempted to restart immediately after it was stopped, the unit can not start for approx. 3 minutes 
this is to protect the compressor.

 

8°C operation (For object pre-heating)

The air conditioner can control the heating temperature to about 8°C in the heating mode.

The 8°C heating operation requires settings with the wired remote controller. Ask the installer or dealer for 
the settings according to the installation manual of the indoor unit.

Start

1. Set the displayed temperature to 18°C in the heating mode by pushing TEMP. 

 button.

2. Set the displayed temperature to 8°C by pushing TEMP. 

 button for at least 4 seconds.

Stop

1. Set the displayed temperature to 18°C by pushing TEMP. 

 button.

•  The air conditioner returns to the normal HEAT mode. Select a desired temperature and operation mode.

NOTE

•  The discharged air temperature is lower than that in the normal heating operation.
•  The room temperature may not be heated evenly depending on the remote controller installation location.
•  The room temperature may not reach 8°C depending on the room size or the installation conditions.
•  Setting for fan speed is available during the 8°C heating operation.

The 8°C heating operation is cancelled in the following cases.

•  When operation is stopped with 

 button.

•  When another operation mode is selected with 

 button.

•  When temperature setting or operation mode is changed or operation is started / stopped by the wireless 

remote controller or the central control remote controller.

•  When this operation mode is used, observe proper operating hours and we recommend that you ask service 

staff for periodic maintenance of the air conditioner.

4

 Operation

When you use the air conditioner for the 

fi

rst time or change the settings, please follow the steps below.

From then on, press the On/Off button to run the air conditioner with the selected settings.

 

Standby

When “SETTING” 

fl

ickers, the operation will not be accepted by system.

REQUIREMENT

•  During use, keep the power switch in open state.
•  When you use it again after a long time, please turn on the power switch at least 12 hours in advance.
•  About 1 minute after the power is turned on, the remote controller can work. This is not a fault.

 

Run operation

Menu button

Set button

ON/OFF button

1

ON/OFF button

Press the button to light up the running indicator, 
and start running.

2

Select running mode

Switch to the running mode by pressing the menu 
button.
•  The current running mode icon 

fl

 ickers.

Press the set button each time, then the running mode 
and its icons change in the following order :

Auto

Dry

Cool

Fan

Heat

(Dehumidify)

• “   Dehumidify” is not available for concealed duct 

high static press type.

•  If the button is not operated within 30 seconds, the 

running mode selection will end.

3

Select the fan speed

Switch to the fan speed mode by pressing the 
menu button.
•  The current fan speed icon 

fl

 ickers.

Press the set button each time, then the fan speed 
mode and its indication change in the following order :

Auto

Low Low +

Med.

Med. +

High

•  The fan speed that can be set will vary depending on 

the connected indoor units.
In the fan mode, “ 

 Auto” cannot be selected.

•  These models that cannot set the fan speed will 

display “ 

 ”.

•  If the button is not operated within 30 seconds, the 

fan speed selection will end.

4

Temperature selection

Press the set button to adjust the temperature.
•  Temperature setting range is from 18.0°C 

to 29.0°C

•  The sensitivity of temperature adjustment is 

0.5°C.

Содержание RAV-HM1101BTP-E

Страница 1: ...IR CONDITIONER SPLIT TYPE Owner s Manual Indoor Unit Model name For commercial use English Concealed Duct Type RAV HM561BTP E RAV HM801BTP E RAV HM901BTP E RAV HM1101BTP E RAV HM1401BTP E RAV HM1601BTP E ...

Страница 2: ...e Cleaning and user maintenance shall not be made by children without supervision According to IEC 60335 1 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Childre...

Страница 3: ...ively he or she has been instructed in such operations by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to these operations The qualified service person who is allowed to do the electrical work involved in installation repair relocation and removal has the qualifications pertaining to this electrical work as stipulated by the local ...

Страница 4: ...air conditioner wear shoes with protective toe caps protective gloves and other protective clothing To transport the air conditioner do not take hold of the bands around the packing carton You may injure yourself if the bands should break Before stacking the packing cartons for storage or transportation heed the precautions written on the packing cartons Failure to heed the precautions may cause t...

Страница 5: ...rvice panel of the outdoor unit set the circuit breaker to the OFF position Failure to set the circuit breaker to the OFF position may result in electric shocks through contact with the interior parts Only a qualified installer 1 or qualified service person 1 is allowed to remove the electrical control box cover of the indoor unit or service panel of the outdoor unit and do the work required Insid...

Страница 6: ...ified service person 1 Take steps to ensure that the power will not be turned on by marking out of service near the circuit breaker for instance until qualified service person 1 arrives Continuing to use the air conditioner in the trouble status may cause mechanical problems to escalate or result in electric shocks or other trouble If the fan grille is damaged do not approach the outdoor unit but ...

Страница 7: ...d in the instructions Otherwise it may cause a malfunction or water leak from the unit Prevent any liquid from falling into the remote controller Do not spill juice water or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deteriorated after being used for a long time Leaving them such condi...

Страница 8: ...rant pipe outlet Air discharge Piping panel Information on the transportation handling and storage of the carton Examples of indication on the carton Symbol Description Symbol Description Keep dry Do not drop Fragile Do not lay down 5 cartons Stacking height 6 cartons can be stacked in this case Do not walk on this carton This side up Do not step Handle with care Other cautions Description CAUTION...

Страница 9: ...be displayed when the air conditioner is centrally controlled and used by a central remote controller and other central control devices If the central control prohibits using the remote controller will flash when pressing the ON OFF mode or temperature button on the remote controller indicating that these buttons do not work The settings that can be configured on the remote controller will vary de...

Страница 10: ... during the 8 C heating operation The 8 C heating operation is cancelled in the following cases When operation is stopped with button When another operation mode is selected with button When temperature setting or operation mode is changed or operation is started stopped by the wireless remote controller or the central control remote controller When this operation mode is used observe proper opera...

Страница 11: ...er operation continues WARNING Cleaning the air fi lter and other parts of the air fi lter involves dangerous work in high places so be sure to have a qualifi ed installer or qualifi ed service person to do it Do not attempt it by yourself CAUTION Do not push buttons with wet hands Doing so may result in electric shock Cleaning the air filters When the filter indicator is displayed on the remote c...

Страница 12: ...mediately turn off the circuit breaker and contact the dealer where you purchased the product The switch does not work properly The circuit breaker often blows out You unintentionally put a foreign object or water inside The unit cannot be run even after the cause of the protective device activation is removed Other unusual conditions are found NOTE For environmental conservation it is strongly re...

Страница 13: ... Turn off the main power switch or circuit breaker and then turn them on again Push the ON OFF button on the remote controller to restart Defrosting operation If the outdoor unit is frosted during the heating operation defrosting starts automatically for approximately 2 to 10 minutes to maintain the heating capacity The fans in both indoor and outdoor units will stop during the defrosting operatio...

Страница 14: ...air vent lighting equipment that disturbs discharge air Turbulent airflow may reduce the performance or disable devices Do not use the air conditioner for special purposes such as preserving food precision instruments or art objects or where breeding animals or growing plants are kept This may degrade the quality of preserved materials Do not install the air conditioner over an object that must no...

Страница 15: ...n becomes invalid if technical or operational modifications are introduced without the manufacturer s consent Declaration of Conformity Manufacturer Toshiba Carrier Thailand Co Ltd 144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand TCF holder TOSHIBA CARRIER UK LTD Porsham Close Belliver Industrial Estate Roborough Plymouth Devon PL6 7DB Unite...

Страница 16: ...144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand 1116950288 ...

Отзывы: