manualshive.com logo in svg
background image

Содержание 580.71122

Страница 1: ...Owner s Manual Manual del Propietario ROOM AIR CONDITIONER ACONDICIONADOR DE AIRE DE VENTANA Model Modelo 580 71122 Sears Roebuck and Co Hoffman Estates IL 6017 ibla_R _ www sears com ...

Страница 2: ...structions in this owner s manual Sears will repair this air conditioner free of charge if defective in material or workmanship FULL FIVE YEAR WARRANTY ON SEALED REFRIGERATION SYSTEM For five years from the date of purchase when this air conditioner is operated and mainta ned for normal room cooling according to instructions in this owner s manual Sears will repair the sealed refrigeration system ...

Страница 3: ...grounding plug for protection against shock hazards Your air conditioner must be plugged into in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with outside protective cover in place This could result in ...

Страница 4: ...ible shock hazard the cord must be plugged into a mating grounding type wall receptacle and grounded in accordance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances If a mating wall receptacle is not available it is the personal responsibility and obligation of the customer to have a properly grounded 3 prong wall receptacle installed by a qualified e...

Страница 5: ...ANUAL for future reference The carton is the best way to store unit during winter or when not in use To avoid risk of persbnal injury property damage or product damage due to the weightof this device and sharp edges that may be exposed Air conditionerscovered inthismanualposean excessiveweight hazard Two ormorepeople are needed to move and installthe unit To prevent injuryor strain use properlifti...

Страница 6: ... air conditioner location Carefully place the cabinet on the window inner sill and align the canter mark on the angle front with the center line marked in the window inner sill FIG 3 _ _ Slide the unit out of the cabinet by gripping the base pan handle and pull forward while bracing the cabinet FIG 4 _ _ Cut the FOAM STRIP ITEM I to fit the underside of the window sash Peel off the backing and att...

Страница 7: ...KET ITEM J with screw ITEM G FIG 14 _ITEM G FIG 14 i_l DRAINAGE Be sure to insert the drain pipe into base pan before installation The air conditioner must be installed with a slight tilt to the outside for proper water drainage The air conditioner will drain the excess condensed water through the drain pipe FIG 15 _J BASEPANREAR DRAIN_ FIG 15 B Slide the chassis into the cabinet FIG 16 CAUTION Fo...

Страница 8: ...the L bracket as shown in FIG 22 1 1 2 rain WOOD STRIP MOUNTED 38ram ON TOP OF INNER SILL 1 1 3 4 CLEAP AN_CE FIG 22 REMOVAL FROM WINDOW Turn off and unplugthe air conditioner Remove the front grille See HOW TO REMOVE THE FRONT GRILLE Refer to page 13 Unscrew the side screws that you installedin Step 15 Slide the air conditioner out of the cabinet BE CAREFUL NOT TO DROP IT Hold onto itfirmly the w...

Страница 9: ...ing sound coming from your air conditioner after it is off These are normal coolant noises CAPACITY AND RUNNING TIME Proper unit size is important in deciding the desired comfort for the area you want to cool An undersized unit wilt not have the capability to cool leaving the area uncomfortably warm The proper size is determined by the number of square feet in the area to be cooled indoor and outd...

Страница 10: ...ble air flow 6 Once the room has cooled adjust the TEMP and Mode Control to the setting you find most comfortable NOTE If the air conditioner is turned off wait 3 minutes before restarting This allows pressure inside the compressor to equalize Failure to wait 3 minutes before restarting may cause inefficient operation If you move the TEMP Control to a warmer then immediately back to a cooler setti...

Страница 11: ...t is running Timer sets numberof hoursuntil shut off Thisbuttoncan automatically control the temperatureof the room The temperature can be set within a range of6O Fto 86 F by I F Selectthe lowernumberfor lower temperature of the room Once Timeris set theTemperaturesettingwillraiseby 2 F after 30 rain and 2 F afteranother 30 min Everytime you push Timerbutton it advancesthe Timer setting as follows...

Страница 12: ...hoursuntil shut off Once Timer is set the Temperature setting will raise by 2 F after 30 rain and 2 F after another 30 min Every time you push Timer button it advancesthe Timer setting as follows 1 Hour 2Hours _ 3Hours _ etc START TIME If unit is off Timer sets numberof hours before unit starts Every time you push Timer button it advances the Timer settingas follows t Hour _ 2Hours _ 3Hours _ etc ...

Страница 13: ...tion The cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid appliance wax To ensure continued peak efficiency the condenser coils weather side at unit should be checked periodically and cleaned if they become clogged with soot or dirt from the atmosphere Brush or vacuum exterior coils to remove debris from fins HOW TO REMOVE THE FRONT GRILLE Open the inl...

Страница 14: ... Todefrost thecoil settheMODEto FANor HighCool with the TEMPcontro_ toa highernumber THEAIRCoNOmONERCOOUNG BUTROOM ISTOOWARM NOICEFORMING ONCOOUNOCOILBEHINDINLET GIRILLE Check if Dirtyair filter airrestricted TEMPControl settoowarm Frontof unitis blockedbydrapes blinds fumiture etc Air distributionis resbicted Doors windows rerJisters etc open Coldaireseapes Unit recenfiytumedonin hotroom Then Cle...

Страница 15: ... 15 ...

Страница 16: ... order Parts call Toll Free Model No 580 71122100 1 800 4 MY HOME I 800 469 4663 CAUTION Use the Kenmore part number on all orders no __ t the illustration number CABINET FRONT GRILLE ASSY number 3 A 1 A 2 A 4 A 5 A 11 00 16 ...

Страница 17: ... NO PART NO DESCRIPTION 1 A 3530AR1278A FRONT GRILLE 2 A 3530AR1535A INLET GRILLE 3 A 5231AR1152A AIR FILTER ASS Y 4 A 5990AR2974A VANE 5 A 4758AR7211A LOUVER 6 A 3091AR2286N CABIN ET ASS Y 7 A 4974AR3262E UPPER GUIDE 8 A 3850A20046M LABEL ENERGY 3828A20049P MANUAL OWNER S Functional Parts Non illustrated Parts 17 11 00 ...

Страница 18: ...580 71122100 CAUTION Use the Kenmore part number on all orders no __ tt the illustration number CONTROL BOX ASS Y 11 B 12 B 13 B 11 00 18 ...

Страница 19: ...323A20003D 5 B 6631AQ3201B 6 B 0CZZA20001M 7 B 4H00442F 8 B 4994AR1221A 9 B 3720A10022A 10 B 6871A20117A 11 B 6871A10013J 12 B 3550AR7032A 13 B 6711A20035E POWER CORD ASS Y CLIP CORD CONNECTOR ASS Y THERMISTOR ASS Y WIRE ASS Y CAPACITOR CAPACITOR CLAMP CONTROL BOX PANEL CONTROL DISPLAY ASS Y PWB ASS Y MAIN COVER CONTROL BOX REMOTE CONTROL Functional Parts Non illustrated Parts 19 11 00 ...

Страница 20: ...580 71122100 CAUTION Use the Kenmore part number on all orders no _tt the illustration number AIR HANDLING CYCLE PARTS 2_C 12 C 19 C 13 C 8 C 10 C 18 C 15 C _ 11_77_C 16 C 11 00 20 ...

Страница 21: ... DAMPER 5 C 4960A20005A MOTOR MOUNT 6 C 4681A20027H MOTOR ASS Y 7 C 3072A20001A SCROLL 8 C 5900A20002B FAN TURBO 9 C 5900AR1173A FAN 10 C 3H02932B CLAMP SPRING 11 C 4998AR1496A SHROUD 12 C 4800A10001A BRACE 13 C 5421AR2910E EVAPORATOR ASS Y 14 C 5403AR2921A CONDENSER ASS Y 15 C 4H02023A DRAIN RUBBER 16 C 4H01029D WASHER RUBBER 17 C 3HO2773A DRAIN PIPE 18 C 4790A20022A BARRIER 19 C 3530AR2688D GRIL...

Страница 22: ...580 71122100 CAUTION Use the Kenmore part number on all orders no _tt the illustration number COMPRESSOR PARTS 8 D 7 D 6 D O 10 D 13 D 5 D 2 D 4 D 3 D 1 D 11 D 11 00 22 ...

Страница 23: ...D 6750U L029A 7 D 3550U L004A 8 D 4H01058A 9 D 4H00947A 10 D 5211AR2930A 11 D 5211A20228A 12 D 5211A20131D 13 D 5211AR7059B 14 D 5211A20020S ISOLATOR COMP COMPRESSOR BRACKET WASHER HEXAGON NUTS GASKET OVERLOAD PROTECTOR TERMINAL COVER GASKET NUT TERMINAL COVER NUT TUBE ASS Y DISCHARGE TUBE ASS Y SUCTION TUBE ASS Y EVAPORATOR TUBE ASS Y CONNECTOR TUBE ASS Y CAPILLARY Functional Parts Non illustrate...

Страница 24: ...580 71122100 CAUTION Use the Kenmore part number on all orders no___tt the illustration number INSTALLATION KIT ASS Y 2 E 11 00 24 ...

Страница 25: ...ation number INSTALLATION KIT ASS Y POS NO PART NO DESCRIPTION 1 E 4959AR3402C SIDE CURTAIN ASS Y 2 E 4959AR3402D SIDE CURTAIN ASS Y 3 E 4810AR3240A SILL SUPPORT BRACKET 4 E 1BHD1004006 BOLT 5 E 1NHC1000006 NUT 6 E 4H01785B L BRACKET Functional Parts Non illustrated Parts 25 11 00 i ...

Страница 26: ...at you need to do it yourself call Sears PartsDirectS 1 800 366 PART 1 800 366 7278 6 a m 11 p m CST 7 days a week www sears _n partsdirect To purchase or inquire about a Sears Service Agreement or Sears Maintenance Agreement 1 800 827 6655 7 a m 5 p m CST Mon Sat Para pedir servicio de reparaci0n a domicilio y para ordenar piezas 1 888 SU HOGAR _ 1 888 784 6427 Au Canada pour service en franois 1...

Отзывы: