5.
REFRIGERANT PIPING DIAGRAMS
75
Liquid tank on
x2 CH,CHR
x3 UH only
Distributor strainer
capillary tube
TC Sensor
Indoor unit
Heat exchanger
Strainer
Cooling
Heating
Packed valve
Strainer
Liquid Receiver
Capillary tube
Dryer
Expansion
valve
Check valve
Heat exchanger
TL sensor
Distributor
TE sensor
Refrigerant pipe (Gas)
ø19mm (3/4")
Refrigerant pipe (Liquid)
ø9.5mm (3/8")
P2
Packed valve
Line pressure
Cooling
Heating
P1
High pressure
Low pressure
P2
High pressure
Low pressure
Muffler
X2
Strainer
Accumulator
Compressor
TD Sensor
Four-way valve
High pressure switch
P1
Check joint
Outdoor unit
INDOOR UNIT
OUTDOOR UNIT
MODEL
CAPILLARY
MODEL
MAIN CAPILLARY
RAV-364BH-PE
ø2x400Lx6P
RAV-364CH/CHR-PE
ø2x300Lx7P
RAV-364AH8-PE
ø2.5x500Lx1P
Indoor Unit
RAV-364BH-PE
RAV-364CH/CHR-PE
RAV-364UH-PE
Outdoor Unit
RAV-364AH8-PE
RAV-364UH-PE
ø2.6x200Lx6P
ø2.6x300Lx2P
ø2.6x500Lx2P
5.6