6.
THE REMOTE CONTROLLERS
78
NO.
KEY SWITCH
OUTLINE OF SPECIFICATION
REMARKS
6.1.1
Outline of Remote Controller’s Functions
1
ON/OFF
[ON/OFF]
MODE
1. When this button is pushed once, the air conditioner
is turned on, with this operation lamp coming on.
2. If pushed once more, it will be turned off, the
operation lamp going off.
2
1. Each time this is pressed, the display
changes in the following sequence:
FAN ONLY – COOL – HEAT – AUTO
FAN
3
1. Each time this is pressed, the display
changes in the following sequence:
AUTO – HIGH – MED – LOW
LOUVER
4
1. When this is pressed, the louvers will start
oscillation and the display will illuminate.
2. When it is pressed again, the louvers will stop.
For models with
automatic louvers
only, otherwise:
will be displayed.
18-29
˚
C
Control range
TEMP ADJUST
TIMER ADJUST
5
1. These buttons are used to set the required room
temperatures.
On Timer or
Off Timer only.
6&7
1. When the TIMER ADJUST button is pressed once,
the time changes 10 minutes. If the button is held,
the time changes in 1 hour steps.
2. If the operation LED is illuminated, the timer
operation will start on completion of the setting.
3. If the operation LED is not illuminated, the timer
operation will start on the operation of the ON/OFF
button.
4. The remaining time can be seen throughout the
timer operation.
CHECK Display
8
1. This display appears when the air conditioner is in
the CHECK mode.
2. Use the CHECK button for a malfunction check.
FILTER
CHECK and FILTER
buttons are for the
use of Service
Engineers.
9
1. This display appears after 2500 hours of operation.
Unit LAN address can be set using the [FILTER]
button.
1. Press and hold the [FILTER] button for 5 seconds.
The LCD display should change, as shown below:
2. U
se the
TIMER ADJUST
button to select required address.
3. Press [FILTER] again to save address.
Note:
This facility is enabled by SW02 BIT7=OFF on
the indoor PCB (Factory Default).
RESET
Use a pointed object
to operate the
RESET Key.
10
1. By pressing the RESET Key, the remote controller is
reset by way of hardware. (The setting/display are in
initial values with the check memory cleared.)